Scientific ReportsOpen accessStructural engineering

Lessons from time-dependent deflection in record span prestressed concrete bridges

Tong Teng, Cheng Zhao, Shiyu Wu, Jiateng Li, Zhao Liu

Southeast University · Ministry of Education

Review

Key points

From the paper's conclusion
  • Globally, over 60% of record-span segmentally constructed prestressed concrete (PC) bridges exhibit excessive deflection, severe cracking, and underestimated prestressing losses.

Abstract

Globally, over 60% of record-span segmentally constructed prestressed concrete (PC) bridges exhibit excessive deflection, severe cracking, and underestimated prestressing losses. Decades of practice in continuous girder and rigid-frame PC bridge design have limited the maximum span capacity to about 350 m, mainly due to unreliable design methodologies and software constraints. This study proposes a multi-field time-dependent numerical framework integrating concrete cracking, nonlinear creep, shrinkage, reinforcement behavior, and prestressing tendon relaxation (including threaded bars). Implemented in Abaqus/Standard through user-defined subroutines, the framework enables high-fidelity 3D simulations and is validated on three record-span PC bridges. Results show that nonlinear creep and cracking significantly aggravate deflection, a phenomenon poorly documented in prior studies. The analysis further reveals that downward-curved cantilever tendons are necessary to counter the unreliable prestressing effectiveness of threaded bars. An in-depth evaluation of these bridges highlights that achieving a reasonable finished stress state is essential for controlling long-term deflection. The findings provide valuable insights for improving the design and durability of segmentally constructed PC bridges.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers