Effect of Crown Height Space and Abutment Configuration on the Maximum Recorded Load of Implant-Supported Monolithic Zirconia Crown Assemblies.
Özay Özsoy, Melek Nur Ürün, Şeyda Bektaş, Serdar Polat
Department of Prosthodontics, Faculty of Dentistry, Gazi University, Ankara 06490, Turkey.
Key points
From the paper's conclusion- This in vitro study evaluated the effects of crown height space (CHS) and abutment configuration on maximum recorded load and described post-test damage in implant-supported monolithic zirconia crown assemblies.
Abstract
This in vitro study evaluated the effects of crown height space (CHS) and abutment configuration on maximum recorded load and described post-test damage in implant-supported monolithic zirconia crown assemblies. Sixty specimens were assigned to six groups (n = 10) combining Ti-base or multi-unit configurations with nominal CHS levels of approximately 13.5, 15.5, or 17.5 mm. After 200,000 thermomechanical aging cycles at 50 N with thermal cycling between 5 °C and 55 °C, specimens underwent eccentric vertical loading on the buccal incline of the functional cusp using a 4 mm spherical tip at 1 mm/min. The primary outcome was maximum recorded load (global peak load), not the onset of irreversible damage. Two-way ANOVA indicated a CHS effect (p = 0.012), but no significant effect of abutment configuration (p = 0.128) or interaction (p = 0.627). The CHS effect persisted in the HC3 analysis (p = 0.043). The lowest versus highest CHS comparison remained significant in heteroscedasticity-sensitive analyses; the lowest-versus-intermediate comparison depended on analytical approach. Four zirconia crown fractures occurred in the lowest-CHS Ti-base group; other post-test damage predominantly involved prosthetic connection components. Within these laboratory conditions, CHS influenced assembly-level maximum recorded load without establishing a continuous or linear relationship.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Influence of Abutment Configuration on the Fatigue Survival of Titanium Implant-Abutment Assemblies.Materials (Basel, Switzerland) · 2026
- Influence of Screw Access Hole Diameter and Preparation Method on the Fit and Fracture Resistance of Implant-Supported Monolithic Zirconia Crowns.The International journal of oral & maxillofacial implants · 2026
- Zirconia abutments and reduced crown-to-implant ratios: Insights into stress distribution.Brazilian oral research · 2026
- Clinical Performance and Failure Mechanisms of Zirconia‐Based Toughened Ceramic CrownsInternational Journal of Applied Ceramic Technology · 2026
- Randomized Controlled Clinical Trial Comparing Screw-Retained Monolithic Zirconia Implant Crowns on Standardized Titanium Base Versus Customized Titanium Abutments- 3-Years Data.Clinical oral implants research · 2026
- Static and fatigue behavior of one- and two-piece zirconia implant abutment systems: an in vitro study.Clinical oral investigations · 2026