Eng

Experimental Study on the Effects of Different Contact Structures on Cathode Spots in Vacuum Arcs

Qixun Huang, Haiming Wang, Yongchao Zhao, Dingjia Wang, Miaosheng Zhu, Wen Tan, Jiaqi Xu, Jita Zhong,

Key points

From the paper's conclusion
  • The results characterize resolvable luminous spots and spot groups in fixed-gap, triggered discharges and provide comparative information for contact design.

Abstract

The relationship between magnetic contact configuration and vacuum-arc morphology was investigated using high-speed imaging. Three configurations were compared at a fixed gap of 6 mm and a peak current of 6 kA: a wan-type transverse-magnetic-field (TMF) configuration, an oblique-slot TMF configuration, and a hybrid oblique-slot TMF cathode/coil-type axial-magnetic-field (AMF) anode. The oblique-slot configuration showed more pronounced directional motion and local luminous concentration than the wan-type configuration. The hybrid configuration exhibited a more dispersed multispot distribution in the images at 3–7 ms. Separate gap and peak-current comparisons were then conducted only for the wan-type TMF configuration. At 6 kA and t = 5.0 ms, increasing the gap from 6 to 12 mm reduced the identifiable luminous-region number and total luminous area by 43.8% and 63.1%, respectively. At a 6 mm gap and the same instant, increasing the peak current from 4 to 10 kA increased these quantities by 83.1% and 65.1%, respectively; however, the total area at 10 kA was smaller than at 8 kA. The results characterize resolvable luminous spots and spot groups in fixed-gap, triggered discharges and provide comparative information for contact design. They do not directly quantify microscopic emission sites, surface erosion, or interruption performance.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers