Effect of Denture Base Stiffness on Stress Redistribution in an Idealized Complete-Denture Model Under Static Bilateral Clenching: A Finite Element Analysis.
Jeong-Hee Seo, Jeong-Hyeon Lee, Won-Gi Kim, Sung-Jae Lee, Bongju Kim, Dong-Wook Han
Research and Development Center, DENTIS Co., Ltd., Daegu 41065, Republic of Korea. · National Institute of Food and Drug Safety Evaluation, Ministry of Food and Drug Safety, Osong 28159, Republic of Korea.
Key points
From the paper's conclusion- This study compared rigid and flexible denture base material conditions in an idealized maxillomandibular finite element (FE) model at the final static bilateral clenching step.
Abstract
Denture base elastic-property assignment may influence how mechanical stress is distributed between a complete denture and its supporting tissues. This study compared rigid and flexible denture base material conditions in an idealized maxillomandibular finite element (FE) model at the final static bilateral clenching step. The model represented a fully edentulous geometry with coincident denture-gingiva surfaces connected by a tie constraint. The model did not include an initial interface gap, interface separation or sliding, extraction sockets, tissue remodeling, or time-dependent misfit. Geometry, mesh, boundary conditions, and loading were identical between the two conditions, whereas both the Young's modulus and Poisson's ratio assigned to the denture base differed. The peak magnitude of the minimum principal stress in the gingiva and the model-predicted local peak von Mises stress in the denture base elements were evaluated. Under the adopted mesh configuration, the flexible property assignment was associated with reductions of 28.6% and 35.3% in gingival compressive stress magnitude and increases of 70.5% and 73.9% in local denture base peak stress in the maxilla and mandible, respectively. These local peak differences are exploratory, model-dependent observations and have not been demonstrated to be mesh-independent. The findings do not establish clinical adaptation, contact pressure, tissue protection, deformation, durability, or performance in immediate dentures.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Micro-computed tomography enables in vitro 3D quantification of denture adhesive behavior at denture-mucosa interfaceFrontiers in Biomaterials Science · 2026
- Influence of density-modulus relationships on the predicted biomechanical response of subject-specific mandibular finite element models: comparative analysis with experimental test dataFrontiers in Bioengineering and Biotechnology · 2026
- Balancing Mechanical and Hygienic Requirements in Removable Partial Denture Framework Design: A Narrative Review of Clinical, Finite Element, and Laboratory EvidenceProsthesis · 2026
- Biomechanical Evaluation of Different Posterior Mandibular Implant Configurations Under Bruxism: An FEA Study.Journal of functional biomaterials · 2026
- Biomechanical Comparative Evaluation of the Atrophic Edentulous Mandible Using All-on-4, All-on-5 and All-on-6 Concepts: A Finite Element Analysis.Dentistry journal · 2026
- Finite element analysis of stress distribution in zygomatic implant configurations with different hybrid prosthesis superstructure materialsScientific Reports · 2026