Balancing Mechanical and Hygienic Requirements in Removable Partial Denture Framework Design: A Narrative Review of Clinical, Finite Element, and Laboratory Evidence
Laurențiu Drăguș, Gabriel-Valeriu Popa, Anamaria Zaharescu, Magdalena Rusu-Negraia, Laura-Carmen Cristescu-Budală, Vadana Rareș-Nicolae, Cătălina-Andreea Florea, Marius Moroianu
Key points
From the paper's conclusion- This narrative review examines the evidence underlying contemporary removable partial denture framework design across three streams of investigation that are rarely read together: longitudinal clinical studies, finite element analyses, and in vitro work.
Abstract
Removable partial dentures remain a principal means of rehabilitating partial edentulism when fixed or implant-supported treatment is precluded by anatomical, medical, or economic factors. The rules governing the design of the metal framework were formulated largely through mechanical reasoning and clinical observation, well before the means existed to test them against outcomes, and have been transmitted for several decades with limited comparative validation. This narrative review examines the evidence underlying contemporary removable partial denture framework design across three streams of investigation that are rarely read together: longitudinal clinical studies, finite element analyses, and in vitro work. Successive sections address gingival coverage, finite element evidence on framework components, rest position, contralateral abutments and indirect retention, guide planes, direct retainers, framework materials and digital workflows, and survival, patient-reported outcomes, and implant-assisted designs. The association between coverage of the gingival tissues and gingival inflammation is the element best supported by clinical observation, although the experimental studies are small and short, and the longitudinal cohorts combined planned frameworks with intensive maintenance. Much of the remainder rests on computational or laboratory evidence, which is broadly consistent in direction but of unestablished clinical magnitude, and several values in routine use are conventions rather than derived thresholds. The evidence supports avoiding gingival coverage that the design does not require and treating maintenance as part of the design; it does not identify an optimal framework geometry, and comparative clinical evidence for most mechanical design choices is limited.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Application of Digital Techniques for the Observation and Fabrication of Removable Partial Dentures.Case reports in dentistry · 2026
- Biomechanical effects of titanium alloy removable partial denture framework designs fabricated by selective laser melting in mandibular Kennedy class II partial edentulism: A finite element study.Journal of dental sciences · 2026
- Assessing Esthetic and Functional Benefits of Three Types of Maxillary Partial Denture Designs over Five YearsDentistry Journal · 2025
- Digital era in oral rehabilitation: a scoping review of trends and implications for clinical practice.Brazilian oral research · 2026
- Effect of Denture Base Stiffness on Stress Redistribution in an Idealized Complete-Denture Model Under Static Bilateral Clenching: A Finite Element Analysis.Materials (Basel, Switzerland) · 2026
- Passive Fit in Digital Full-Arch Implant Rehabilitation: A Clinical Application of an Adaptive Titanium Base.Cureus · 2026