Biomechanical Evaluation of Different Posterior Mandibular Implant Configurations Under Bruxism: An FEA Study.
Mehmet Ates, Ceyda Akin
Department of Prosthodontics, Faculty of Dentistry, Necmettin Erbakan University, 42090 Konya, Türkiye.
Key points
From the paper's conclusion- This study evaluated the biomechanical performance of different abutment types, superstructure materials, prosthetic designs, and loading conditions in the implant-supported rehabilitation of three consecutive missing teeth in the mandibular posterior region using three-dimensional finite element analysis (3D-FEA).
Abstract
This study evaluated the biomechanical performance of different abutment types, superstructure materials, prosthetic designs, and loading conditions in the implant-supported rehabilitation of three consecutive missing teeth in the mandibular posterior region using three-dimensional finite element analysis (3D-FEA). Twenty FEA models were constructed, simulating two-implant (pontic, mesial, and distal cantilever) and three-implant (splinted and unsplinted) configurations using multi-unit and Ti-base abutments composed of titanium alloy (Grade 5, Ti-6Al-4V), with monolithic zirconia and zirconia-supported feldspathic porcelain superstructures. Functional and parafunctional (bruxism) vertical and oblique loads were applied to analyze von Mises stresses in the components and principal stresses in the peri-implant bone. The results indicated that two-implant models generated higher stress concentrations than three-implant models, and unsplinted or cantilevered designs produced elevated stresses compared to splinted or pontic designs. Ti-base abutments resulted in greater stress accumulation in the connection complex compared to multi-unit systems. Under vertical and oblique parafunctional forces, stress values on the abutments in distal cantilever models-particularly in unsplinted Ti-base designs under oblique loading-exceeded the yield strength of the Ti-6Al-4V alloy (890 MPa), indicating a substantial risk of plastic deformation. To optimize biomechanical stability, three-implant-supported, splinted designs utilizing Multi-unit abutments should be prioritized. Avoiding distal cantilevers and unsplinted designs is critical in patients with bruxism to minimize the risk of mechanical failure in the Ti-6Al-4V components.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Finite element analysis of stress distribution in zygomatic implant configurations with different hybrid prosthesis superstructure materialsScientific Reports · 2026
- Clinical and Finite Element Evaluation of Fixed Implant Prosthesis Designs for the Edentulous MandibleClinical Implant Dentistry and Related Research · 2026
- Biomechanical Comparative Evaluation of the Atrophic Edentulous Mandible Using All-on-4, All-on-5 and All-on-6 Concepts: A Finite Element Analysis.Dentistry journal · 2026
- Biomechanical Comparison of All-on-Four and Interforaminal All-on-Six Concepts Using Titanium and Ti-Zr (Roxolid®): A Nonlinear Finite Element Study.Journal of stomatology, oral and maxillofacial surgery · 2026
- Biomechanical Behavior of Monolithic Zirconia Prosthodontic Restorations in Maxillary Posterior Teeth with Reduced Periodontium: A Finite Element Analysis.Materials (Basel, Switzerland) · 2026
- Bite Force Analysis Using Numerical Simulation with Different Prosthesis Anchorages.Biomimetics (Basel, Switzerland) · 2026