Reliability of Ocular Surface and Biometric Measurements Under Face Mask Exposure: A Narrative Review.
Guillermo Rodríguez Iranzo, Cristina Peris Martínez
Fundación de Oftalmología Médica de la Comunidad Valenciana (FOM), Pío Baroja 12, 46015 Valencia, Spain.
Key points
From the paper's conclusion- This structured approach incorporates targeted ocular surface assessment and management, including optimization of mask fit and tear film therapy when clinically indicated, to guarantee patient comfort and predictable postoperative visual outcomes.
Abstract
Background: The widespread global adoption of facial respiratory barriers across diverse clinical and public environments has led to a significant increase in specialized consultations regarding unexpected ocular irritation and surface dryness. This clinical presentation, often secondary to mask-associated ocular symptoms, represents a unique challenge for accurate preoperative assessment in cataract surgery. This narrative review provides a comprehensive and critical evaluation of the literature exploring the relationship between mask-induced microenvironmental stress, patient-reported symptoms and objective tear film parameters, focusing specifically on their distinct impacts on preoperative ocular biometry and diagnostic measurement reliability for cataract surgery planning. Methods: A screening of published clinical studies and cohorts evaluating questionnaires, non-invasive tear film kinetics, epithelial structural changes and high-resolution automated topography was conducted across major biomedical databases up to April 2026 to evaluate underlying patterns, clinical associations and research gaps. Results: The available evidence suggests a distinct and reproducible dissociation between ocular surface symptoms and objective parameters. While improperly fitted superior mask margins may direct continuous, asymmetric warm convective air currents upward over the periorbital region-a mechanism hypothesized to accelerate tear evaporation and contribute to ocular surface discomfort-the evidence regarding biometric technology vulnerability remains constrained to limited sample sizes. Early automated measurements, particularly deeper metrics such as axial length, show good reproducibility under specific mask exposure settings, whereas superficial tear-film-dependent measurements require careful isolation. Conclusions: Strategic preoperative pathways must differentiate acute, transient microenvironmental alterations from persistent or progressive pre-existing ocular surface disease. Clinical screening workflows should incorporate cautious terminology and the optimization of mask fit or targeted mask removal should be actively considered during automated data acquisition, particularly for patients with compromised ocular surfaces. This structured approach incorporates targeted ocular surface assessment and management, including optimization of mask fit and tear film therapy when clinically indicated, to guarantee patient comfort and predictable postoperative visual outcomes.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Regional Tear Film Quality Changes Across Eye Gaze Directions Revealed by Spatial Mapping and Threshold Sensitivity Analysis.Journal of clinical medicine · 2026
- Contact lens microplastics: rapid Py-TOFMS quantification and ocular health risk assessment.The Analyst · 2026
- Reference Estimates of Mean Tear Film Lipid Layer Thickness Measured with LipiView® and LipiView II® in Healthy Adults: A Systematic Review and Meta-Analysis.Journal of clinical medicine · 2026
- Effect of Preoperative Ocular Surface Optimization on Biometric Accuracy and Refractive Outcomes After Cataract Surgery: A Systematic Review with Narrative and Exploratory Quantitative Synthesis.Clinical ophthalmology (Auckland, N.Z.) · 2026
- A scoping review of integrated blink analysis technologies for ocular surface diseases.Eye (London, England) · 2026
- Tear Dynamics During Fenestrated Scleral Lens Wear: A Pilot StudyOphthalmic and Physiological Optics · 2026