A scoping review of integrated blink analysis technologies for ocular surface diseases.
Chee Wui Ong, Blanche Xiaohong Lim, Sanjiv K Bhatia, Tjaart van der Walt, Tareq Nabhan, Chris Hong Long Lim
Department of Ophthalmology, National University Hospital, Singapore, Singapore. · Department of Computer Science, University of Missouri-Saint Louis, Saint Louis, MO, USA.
Key points
From the paper's conclusion- We included studies describing the use of integrated technologies to capture and analyse blink metrics for the evaluation of dry eye disease and other ocular surface conditions.
Abstract
The purpose of this review is to describe integrated technologies for blink analysis and their utility in evaluating ocular surface diseases. A literature search was conducted using PubMed, Embase, and CENTRAL from January 1, 2000, to August 17, 2025. Search terms included "Eye Blink", "Blink", "Blinking", "Device", "Technology", "Appliance", and "Application". We included studies describing the use of integrated technologies to capture and analyse blink metrics for the evaluation of dry eye disease and other ocular surface conditions. Publications describing technical engineering aspects or technologies without evaluation of ocular surface diseases were excluded. Findings from relevant studies were extracted and compared. Of 3275 identified records, 42 met inclusion criteria. We evaluated the use of 9 technologies. These comprised desk-bound devices(Intelligent Vision Sensor, LipiView™, and IDRA) , wearable devices (Wink Glass, Blink-sensing Glasses), and smartphone or computer applications(HealthyRoad, DryEyeRhythm, Dry eye or not? and EyeScore) . LipiView™ and IDRA were most commonly studied. Blink rate and partial blink rate were the most commonly analysed parameters, and DED was the most commonly evaluated ocular surface condition. Consistent with existing literature, studies demonstrated associations between increased partial blink rates and ocular surface compromise. There was however heterogeneity in methods of blink analysis and insufficient validation of the accuracy and diagnostic ability of measured blink parameters for ocular surface conditions. Integrated blink analysis technologies are promising for the assessment of ocular surface diseases. Further studies are needed to evaluate the validity, reliability, and clinical utility of these technologies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Videographic evaluation of blinking patterns and their association with dry eye.Orbit (Amsterdam, Netherlands) · 2026
- Timing of Digital Device Exposure as a Source of Measurement Error in Dry Eye Disease Research: A Critical Narrative Review.Cureus · 2026
- Advances in Long-Acting Ocular Therapies for Dry Eye Disease: Delivery Systems, Formulations, and Clinical Perspectives.Experimental eye research · 2026
- Multiplexed tear diagnostic intelligence at the point of care: toward clinically informative biomarker panels.Chemical communications (Cambridge, England) · 2026
- Systematic Performance Evaluation of WebGazer Webcam-Based Eye Tracking with Spatial and Angular Error Analysis.Journal of eye movement research · 2026
- Ocular Surface Damage and Blink Dynamics Associated with High-intensity Smartphone Use.The ocular surface · 2026