Tear Dynamics During Fenestrated Scleral Lens Wear: A Pilot Study
Damien Fisher, Asif Iqbal, David Alonso-Caneiro, Michael J. Collins, Stephen J. Vincent
Queensland University of Technology · Vision Cooperative Research Centre
Key points
From the paper's conclusion- Future research utilising the developed technique may provide further insights into tear exchange during scleral lens wear with different fenestration sizes and configurations.
Abstract
PURPOSE: To develop a Scheimpflug-based image analysis technique to quantify tear exchange during scleral lens wear and investigate fluid reservoir tear dynamics during fenestrated lens wear. METHODS: Nine healthy participants wore a scleral lens (KATT™, Capricornia Contact Lenses) with a single 0.3 mm diameter limbal fenestration in one eye for 90 min. Central (0-2.5 mm from the corneal apex) and peripheral (-1.0 to 0 mm from the scleral spur) stromal cornea oedema was measured using optical coherence tomography. Scheimpflug images were obtained during lens wear at multiple time points following the application of sodium fluorescein to the bulbar conjunctiva. These images were exported and annotated manually to select the region of interest (the fluid reservoir) from which the intensity of each pixel was extracted to provide a measure of fluorescent intensity (in arbitrary units [AU] on a scale of 0-255) throughout lens wear across the central 10 mm. RESULTS: The coefficient of repeatability for central fluid reservoir intensity measurements was 7 AU (on a scale of 0-255 AU). Fluid reservoir fluorescent intensity varied with measurement location (p < 0.001), being greater towards the periphery (4 and 5 mm from the centre). On average, intensity differences between the peripheral and central fluid reservoir diminished within 10 min of sodium fluorescein application. Two patterns of tear dynamics were observed and were classified as low and high flow. Low flow participants (n = 6) exhibited greater central (3.72× more) and peripheral (2.25× more) corneal oedema, but the difference was not statistically significant. CONCLUSIONS: The ingress and mixing of sodium fluorescein within the fluid reservoir stabilised between central and peripheral locations after 10 min of fenestrated scleral lens wear. Two patterns of tear dynamics were observed (low and high flow), with low flow participants exhibiting greater corneal oedema. Future research utilising the developed technique may provide further insights into tear exchange during scleral lens wear with different fenestration sizes and configurations.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- The Effect of Limbal Fenestrations on Scleral Lens-Induced Central Corneal OedemaOphthalmic and Physiological Optics · 2026
- Identifying ocular surface indicators of initial performance in standard soft contact lenses.Contact lens & anterior eye : the journal of the British Contact Lens Association · 2026
- Total Corneal Aberration Measurements by Anterior Segment Optical Coherence Tomography and Scheimpflug-Based Imaging: A Narrative Review of Optical Principles and Sources of Inter-Device Discordance.Journal of clinical medicine · 2026
- Regional Tear Film Quality Changes Across Eye Gaze Directions Revealed by Spatial Mapping and Threshold Sensitivity Analysis.Journal of clinical medicine · 2026
- Influence of Room Illumination on Corneal Densitometry.Translational vision science & technology · 2026
- Improving limbal fit in scleral lenses: challenges, advances, and clinical strategies.Clinical & experimental optometry · 2026