Deep-Learning-Based Corneal Segmentation in Post-Mortem OCT
Matteo Nioi, Pietro Emanuele Napoli, Elia Porru, Domenico Nieddu, Alberto Chighine, Emanuela Locci, Ernesto d’Aloja
Key points
From the paper's conclusion- These findings demonstrate the feasibility of automatic whole-cornea segmentation across heterogeneous post-mortem OCT appearances, supported by high reproducibility of manual reference delineation and comparable performance with an alternative segmentation architecture, and provide a methodological basis for broader external validation and future quantitative applications in post-mortem ocular im
Abstract
Optical coherence tomography (OCT) has increasingly been applied to post-mortem ocular imaging; however, automated corneal segmentation methods have been developed almost exclusively for in vivo conditions and may be challenged by the marked morphological alterations and imaging artifacts encountered after death. This study aimed to develop and quantitatively evaluate a deep-learning-based framework for automatic whole-cornea segmentation in post-mortem OCT. A custom U-Net was developed using 138 manually annotated B-scans from 35 cases, with case-level separation into training and internal validation subsets. The final model was quantitatively evaluated on a dedicated ground-truth subset of 34 B-scans representing early, intermediate, advanced, thin, and artifact-prone post-mortem corneal appearances. An additional independent evaluation was conducted on 40 manually annotated B-scans from five individuals excluded from model development. Segmentation performance was assessed using the Dice similarity coefficient, Intersection-over-Union (IoU), precision, recall, and 95th-percentile Hausdorff distance (HD95). Intra- and inter-observer reproducibility of manual whole-cornea segmentation was additionally assessed in a dedicated subset of 24 B-scans, and a same-dataset architectural benchmark against DeepLabV3+ was performed. A rule-based boundary-focused post-segmentation quality-control procedure, incorporating the Boundary-focused Corneal Quality Index (BCQI), was applied to a larger dataset of 205 B-scans without manual reference masks. On the 34-B-scan ground-truth evaluation subset, the model achieved a median Dice coefficient of 0.947, IoU of 0.899, precision of 0.999, recall of 0.903, and HD95 of 7.62 pixels (IQR, 7.00–8.30). An additional analysis using anisotropic spatial calibration yielded a median HD95 of 58.33 µm (IQR, 51.31–66.67), with greater variability at the posterior than at the anterior corneal boundary. In the independent 40-B-scan evaluation, mean Dice was 0.9403, while mean posterior boundary error exceeded anterior boundary error (9.38 vs. 5.79 pixels). Manual segmentation showed high reproducibility, with median Dice coefficients of 0.967 for intra-observer and 0.944 for inter-observer agreement. DeepLabV3+ showed closely comparable overall segmentation performance, with no statistically significant differences across the five evaluated metrics after Holm correction. The combination of near-unity precision, lower recall, and lower predicted than reference mask coverage indicated a mild systematic tendency toward under-segmentation. In the larger application dataset, the predefined rule-based QC procedure classified 184/205 segmentations (89.8%) as OK and 21/205 (10.2%) as WARN, with no FAIL classifications. However, exploratory ground-truth-based assessment revealed limited QC sensitivity for detecting segmentation errors, indicating that favorable BCQI classifications cannot substitute for anatomical validation. These findings demonstrate the feasibility of automatic whole-cornea segmentation across heterogeneous post-mortem OCT appearances, supported by high reproducibility of manual reference delineation and comparable performance with an alternative segmentation architecture, and provide a methodological basis for broader external validation and future quantitative applications in post-mortem ocular imaging.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- AI-empowered OCT is non-inferior to IVUS for media and plaque burden quantification: head-to-head histopathology validation using human coronary arteriesEuropean Heart Journal · 2026
- Effect of annotation strategy on deep learning-based intracranial hemorrhage segmentation in postmortem computed tomography.Legal medicine (Tokyo, Japan) · 2026
- CoNV-AutoGrader: A Deep Learning System for Automated Severity Grading of Corneal Neovascularization From Slit-Lamp Images.Translational vision science & technology · 2026
- Donor endothelial grading and specular images did not measurably improve graft-failure prediction over a clinical reference in the Cornea Preservation Time StudyFrontiers in Medicine · 2026
- Task-Specific Quality Gating for Retinal Optical Coherence Tomography B-Scans: Learned Representations Over Scalar Metrics in Choroid SegmentationmedRxiv · 2026
- AI-enhanced 3D-OCT analysis for automated mapping of layer thickness in paintings.Optics express · 2026