CoNV-AutoGrader: A Deep Learning System for Automated Severity Grading of Corneal Neovascularization From Slit-Lamp Images.
Ruobing Xia, Junhao Xia, Zitao Liu, Chenhang Ding, He Xie, Jinyang Li, Haiou Wang, Wei Chen
National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, Wenzhou, People's Republic of China. · School of Architecture, Tsinghua University, Beijing, People's Republic of China.
Key points
From the paper's conclusion- CoNV-AutoGrader enables automated, objective, and reproducible CoNV severity grading directly from slit-lamp images, achieving strong agreement with expert grading and consistent performance across diverse clinical scenarios.
Abstract
PURPOSE: The purpose of this study was to develop and validate a fully automated framework (CoNV-AutoGrader) for clinically interpretable severity grading of corneal neovascularization (CoNV) from slit-lamp photographs. METHODS: A retrospective dataset of 200 slit-lamp images with CoNV was collected from a tertiary eye center. Corneal and CoNV regions were manually annotated and quality controlled by ophthalmologists. CoNV-AutoGrader integrates two U-Net-based segmentation models for corneal region and neovascularization detection with a deterministic geometric scoring module based on a standardized clinical grading system incorporating quadrant involvement and centripetal extent. Model performance was evaluated using five-fold cross-validation and quantified with Dice coefficient, F1 score, intersection over union (IoU), continuous linear Dice (clDice), accuracy, sensitivity, specificity, precision, and area under the receiver operating characteristic curve (AUC). Agreement between automated and expert grading was assessed using intraclass correlation coefficient (ICC) and Bland-Altman analysis. RESULTS: For corneal region segmentation, the model achieved a mean Dice coefficient of 0.971 ± 0.003 and AUC of 0.992 ± 0.003. For CoNV segmentation, the mean Dice coefficient was 0.405 ± 0.011, sensitivity was 0.522 ± 0.037, and AUC was 0.872 ± 0.013. The automated severity score demonstrated good agreement with expert ratings (overall ICC = 0.918, P < 0.001). Bland-Altman analysis demonstrated good agreement between automated predictions and ophthalmologist-assigned scores, with negligible systematic bias and limits of agreement within clinically acceptable ranges. CONCLUSIONS: CoNV-AutoGrader enables automated, objective, and reproducible CoNV severity grading directly from slit-lamp images, achieving strong agreement with expert grading and consistent performance across diverse clinical scenarios. TRANSLATIONAL RELEVANCE: By transforming U-Net-based vessel segmentation into standardized clinical severity metrics, this framework bridges algorithmic image analysis and real-world CoNV management.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparative Evaluation of Multiple Deep Learning Models for Six-Class Keratitis Classification.Translational vision science & technology · 2026
- Deep Learning Model for Image-Based Classification of Four Keratitis Categories.Cornea · 2026
- Automated Nonperfusion Quantification in Diabetic Retinopathy on Ultra-Widefield Swept-Source OCT AngiographyOphthalmology Science · 2026
- Automated quantification of central corneal epithelial thickness for the diagnosis of limbal stem cell deficiency.PloS one · 2026
- Automated Regional Detection of Intervortex Venous Anastomosis on Ultra-Widefield Indocyanine Green Angiography Using a Two-Stage Deep Learning Framework.Journal of clinical medicine · 2026
- Clinical Validation of a Novel Imaging Method for Conjunctival Hyperemia: Red Intensity Coefficient Analysis Using the MR-6000 System.Eye & contact lens · 2026