Three-Dimensional Visualization of Scattered Radiation Sources with a Scintillator-Coupled CMOS Camera in C-Arm-Guided Thoracolumbar Spine Surgery.
Toshioh Fujibuchi, Donghee Han
Division of Medical Quantum Science, Department of Health Sciences, Faculty of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan. · Department of Radiological Science, Kangwon National University, Samcheok 25949, Republic of Korea.
Key points
From the paper's conclusion- Surgeons performing thoracolumbar spine surgery under mobile C-arm fluoroscopy receive scattered radiation whose spatial distribution cannot be seen.
Abstract
Surgeons performing thoracolumbar spine surgery under mobile C-arm fluoroscopy receive scattered radiation whose spatial distribution cannot be seen. A visualization system combining a pinhole collimator, a cesium iodide scintillator, a high-sensitivity complementary metal-oxide-semiconductor (CMOS) camera and a depth camera was placed at the surgeon's position, and its images were composed on a three-dimensional point cloud of the operating room. A torso phantom was irradiated once per condition in the lateral (LR) and under-table (AP) projections, without a movable lead-glass plate and with it at two heights. Sources appeared on the beam-entrance surface and the operating table. At the pinhole, 140 cm above the floor, the dose rate without the plate was 29.7 mSv/h (LR) and 15.6 mSv/h (AP), 9.6 and 5.0 µSv per exposure, a ratio of 1.9; a lower edge at 135 cm gave no measurable reduction, and at 120 cm the dose rate fell by 20% (LR) and 6% (AP). Monte Carlo simulation with a validated model of the same tube head gave a ratio of 1.90 at the measurement position and reproduced the null at 135 cm. Projection choice mattered more than plate position.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Operator Radiation Dose in C-Arm Fluoroscopy: A Narrative Review of Region- and Procedure-Specific Evidence and a Practical Framework for Intraoperative Dose EstimationSurgeries · 2026
- Mobile radiation shielding device for scatter dose reduction during portable radiography in an orthopedic ward.PloS one · 2026
- Radiation in Spine Care: A Comprehensive Review of Radiation Sources, Emerging Technology, Cancer Risk, and Radiation Stewardship.The spine journal : official journal of the North American Spine Society · 2026
- The Best of Both Worlds: Combining Freehand and Mobile Intraoperative CT-Navigated Instrumentation in Pediatric Deformity Corrections—A Retrospective Case Series of 31 Consecutive PatientsSurgical Techniques Development · 2026
- O-arm Navigation-assisted Extreme Lateral Interbody Fusion Utilizing SureTrak Device.Neurologia medico-chirurgica · 2026
- Evaluation of occupational radiation exposure and safety practices among orthopedic surgeons using C-arm fluoroscopy: a preliminary study at a hospital in Palestine.Radiation protection dosimetry · 2026