Detectable, Task-Relevant, or Harmful? Construct-Valid Evaluation of Unlabeled Distribution-Shift Monitoring in Chest Radiography.
Dan Gabriel Badea, Răzvan-Andrei Rotaru, Răzvan Victor Rughiniș, Flavia Zaim-Oprea, Dinu Țurcanu, Daniel Rosner
Faculty of Automatic Control and Computers, National University of Science and Technology POLITEHNICA Bucharest, 060042 Bucharest, Romania. · Faculty of Electronics and Telecommunications, National Institute of Innovations in Cybersecurity "CYBERCOR", Technical University of Moldova, 168 Ștefan cel Mare Blvd, MD-2004 Chișinău, Moldova.
Key points
From the paper's conclusion- The results show that detectability, task relevance, and metric-specific harm are distinct constructs and should be reported separately.
Abstract
Distribution-shift alarms do not establish classifier harm. We evaluated the detectability, frozen-head relevance, and performance deterioration of two public DenseNet-121 chest-radiography classifiers under 30 controlled image conditions. Signals covered pixels, 64-component PCA representations, logits, probabilities, and calibrated high-error selection. An exact whole-model-null intervention changed representations while preserving all 18 released output slots to within 4.09 × 10-14; PCA monitoring detected all six interventions, five-logit monitoring detected none, and the paired Brier change was negligible. Across image shifts, PCA and logit alarm rates were 97% and 52%. In held-source/held-family prediction of primary Brier harm, probability mean displacement had the lowest error (MAE 0.00679); neither PCA signal outperformed the training-mean baseline after correction, whereas three output-facing signals beat both prespecified baselines. Secondary results were outcome-dependent: PCA RFF-MMD ranked best for macro-AUC and locked-F1 loss. An exploratory ConvNeXtV2-Atto/MobileViT-XS arm reproduced the construct separation: representation monitoring detected 57/60 conditions and all six task-null controls, while logit monitoring detected no task-null control; probability mean had the lowest held-architecture/held-family Brier-harm error ratio (0.404). The results show that detectability, task relevance, and metric-specific harm are distinct constructs and should be reported separately.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Out-of-Distribution Generalization of Pretrained Multi-Label Chest X-Ray Classifiers: A Retrospective External Validation of Seven Models.Diagnostics (Basel, Switzerland) · 2026
- Diagnosing Low-Confidence Patient Profiles via Localized Harmful Covariate Shift DetectionarXiv · 2026
- Calibration, Uncertainty, and Data Efficiency of Deep Learning Chest Radiograph Classifiers Under Cross-Dataset Distribution Shift: A Multi-Dataset BenchmarkmedRxiv · 2026
- Can saliency maps flag chest radiograph classifier errors at a new hospital? An external validation studyarXiv · 2026
- Counterfactual Model Testing Under Distribution ShiftarXiv · 2026
- Beyond Benchmark Scores: Auditing Medical Vision-Language Models for Chest X-Ray Tuberculosis ScreeningarXiv · 2026