Calibration, Uncertainty, and Data Efficiency of Deep Learning Chest Radiograph Classifiers Under Cross-Dataset Distribution Shift: A Multi-Dataset Benchmark
F. Shamim, R. A. Hussain
Key points
From the paper's conclusion- Purpose To evaluate the external transportability of source-derived probability calibration for chest radiograph deep learning classifiers under distribution shift and determine its dependence on sample size and disease prevalence.
Abstract
Purpose To evaluate the external transportability of source-derived probability calibration for chest radiograph deep learning classifiers under distribution shift and determine its dependence on sample size and disease prevalence. Materials and Methods This retrospective secondary computational analysis of public, de-identified radiographic datasets involved no participant contact or new data collection. Cohort sizes were prespecified by availability without prospective power calculation: 106,686 NIH ChestX-ray14 images (29,323 patients; 1992-2015) for development and internal testing, 20,000 CheXpert images (20,000 patients; October 2002-July 2017), and 14,998 VinBigData images (2018-2020) for external testing. ResNet-18, DenseNet-121, and DeiT-Tiny classifiers for cardiomegaly and pleural effusion were trained across four patient fractions and three seeds (36 fits). Calibrators were fitted exclusively on NIH data. Twelve primary external Brier-score contrasts (temperature-scaled versus raw probabilities) were evaluated using paired cluster-bootstrapping with Holm adjustment. Results Temperature scaling reduced Brier scores in nine of 12 primary contrasts but worsened pleural effusion calibration on VinBigData across all architectures (Brier increases: ResNet-18, 0.001460 [95% CI: 0.001347, 0.001568]; DenseNet-121, 0.001193 [95% CI: 0.001109, 0.001274]; DeiT-Tiny, 0.000498 [95% CI: 0.000417, 0.000577]; all adjusted P=.006). Standardizing class weights to NIH prevalence reversed all CheXpert improvements. Although full versus 10% training improved external AUROC across all comparisons, DeiT-Tiny CheXpert pleural effusion Brier score worsened by 0.007039 despite a 0.032466 AUROC gain. At 80% selective image retention, calibrated ensembles retained only 12.3%-17.2% of VinBigData positive pleural effusion examinations. Conclusion Source-fitted calibration is not uniformly transportable across health systems, and discrimination gains do not guarantee calibrated probabilities. External evaluation must simultaneously assess probability reliability, prevalence shifts, and retained-case composition.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Out-of-Distribution Generalization of Pretrained Multi-Label Chest X-Ray Classifiers: A Retrospective External Validation of Seven Models.Diagnostics (Basel, Switzerland) · 2026
- When Should We Trust Medical Image Models? Evaluating Confidence Reliability under Cross-Dataset ShiftarXiv · 2026
- Uncertainty-driven training for three-dimensional calibrated lung nodule classificationarXiv · 2026
- Calibration failure and limited-label recalibration of retinal image classifiers under dataset shiftDiscover Artificial Intelligence · 2026
- Deep Learning Architecture Comparison for Pneumonia Detection in Pediatric Chest X-Rays: Ensemble Learning and Cross-Population External EvaluationApplied Sciences · 2026
- Evaluation Choices Shape Biomedical ML Claims: A Pediatric Pneumonia Benchmark Case StudyarXiv · 2026