Out-of-Distribution Generalization of Pretrained Multi-Label Chest X-Ray Classifiers: A Retrospective External Validation of Seven Models.
Paulius Bundza, Justas Trinkūnas
Department of Information Systems, Faculty of Fundamental Sciences, Vilnius Gediminas Technical University, Saulėtekio Al. 11, 10223 Vilnius, Lithuania.
Key points
From the paper's conclusion- Local validation, recalibration, and subgroup-stratified reporting are needed before clinical use.
Abstract
Background/Objectives: Chest radiograph classifiers are usually benchmarked within their training distribution, whereas deployment exposes them to new populations, equipment, and labeling conventions. This study quantified out-of-distribution (OOD) performance of seven public pretrained classifiers. Methods: Six DenseNet-121 models and one ResNet-50 TorchXRayVision model were evaluated without fine-tuning on 18,424 Brazilian BRAX studies for seven common labels. The in-distribution (ID) performances of the three models trained on ChestX-ray14 were measured on held-out patients. Areas under the receiver operating characteristic curve (AUROC) were compared with a paired patient-level bootstrap; calibration, operating points, and subgroups were assessed. Results: OOD macro AUROC was 0.733-0.741 for three models trained with PadChest and 0.652-0.677 for four single-source models (all between-group differences significant). Relative to held-out ID performance, macro AUROC decreased by 6.0-11.4 percentage points. Expected calibration error of default outputs (0.028-0.392) largely reflected score normalization and fell to 0.001-0.003 after recalibration; sensitivity at default operating points was 0.035-0.797. Macro AUROC was lower for anteroposterior than posteroanterior radiographs (0.499-0.605 vs. 0.691-0.796), also within age groups; residual confounding remains possible. Conclusions: In this single Brazilian cohort, ID benchmarks overestimated external performance, and default outputs and operating points did not transfer. Local validation, recalibration, and subgroup-stratified reporting are needed before clinical use.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Calibration, Uncertainty, and Data Efficiency of Deep Learning Chest Radiograph Classifiers Under Cross-Dataset Distribution Shift: A Multi-Dataset BenchmarkmedRxiv · 2026
- Deep Learning Architecture Comparison for Pneumonia Detection in Pediatric Chest X-Rays: Ensemble Learning and Cross-Population External EvaluationApplied Sciences · 2026
- Detectable, Task-Relevant, or Harmful? Construct-Valid Evaluation of Unlabeled Distribution-Shift Monitoring in Chest Radiography.Journal of imaging · 2026
- Med-AR: Autoregressive Vision-Language Pretraining for Long-Tailed Chest X-Ray Classification and Uncertainty-Aware EvaluationarXiv · 2026
- Is a CNN-Transformer Ensemble Worth It When a Chest X-Ray Foundation Model Is Available?arXiv · 2026
- Uncertainty‐suppressed long‐tailed learning with lightweight feature adaptation for multi‐label chest X‐ray classificationJournal of Applied Clinical Medical Physics · 2026