Comparative Evaluation of Initial Horizontal and Occlusal Forces Generated by Orthodontic Aligners Fabricated with Different Materials.
Pablo Echarri, María José González-Olmo, Matias Gabriel Sivak, Javier Echarri, Manuel Lagravere, Martín Romero Maroto
Athenea Dental Institute, San Jorge University, 50830 Zaragoza, Spain. · Department of Orthodontics, Rey Juan Carlos University, 28922 Madrid, Spain.
Key points
From the paper's conclusion- These findings support further investigation of this monolayer material under additional laboratory and clinical conditions.
Abstract
UNIQ (Scheu Dental GmbH, Hilden, Germany) is a recently introduced monolayer copolyester aligner material whose initial biomechanical behavior has not yet been compared with that of established multilayer aligner materials. This in vitro study compared the initial orthodontic forces generated by UNIQ and Zendura FLX during buccolingual and occlusogingival displacement of a maxillary central incisor. Aligners made from Zendura FLX 0.76 mm and UNIQ 0.625 mm were thermoformed over identical 3D-printed maxillary arch models and tested with the Orthodontic Simulator (OSIM) at the Craniofacial Biomechanics and Biomaterials Research Group, University of Alberta. Displacements were applied in 0.05 mm increments up to 2 mm, with repeated load-cell measurements performed at each step. Both materials showed progressive force increases with displacement. Zendura FLX generated slightly higher buccolingual forces at most displacement levels, but the differences were not statistically significant; occlusogingival forces were similar across most displacement levels, although a larger between-material difference was observed at 2 mm of displacement. Within the limitations of this in vitro model, no statistically significant differences in overall force-displacement response were detected between UNIQ and Zendura FLX under the experimental conditions evaluated. These findings support further investigation of this monolayer material under additional laboratory and clinical conditions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Initial Force Expression of Different Clear Aligner Systems in a Simulated Maxillary Canine Distalization Model with Lateral Incisor Agenesis: An In Vitro Comparative Study.Bioengineering (Basel, Switzerland) · 2026
- In Vitro Comparison of Initial and 7-Day System-Level Resultant Forces in Clear Aligners with Different Layer Structures.Bioengineering (Basel, Switzerland) · 2026
- Comparative analysis of experimental torque behavior and physicochemical properties of commercial and in‑house orthodontic aligners.Journal of the World federation of orthodontists · 2026
- Mechanical properties of thermoformed and direct-printed aligner materials after immersion in 37 °C water: a 14-day in vitro studyScientific Reports · 2026
- Next-Generation Orthodontics: Functional Resins, Biomechanics, Biocompatibility, and Current Clinical Reality of Direct 3D-Printed AlignersJournal of Functional Biomaterials · 2026
- Direct 3D-Printed Clear Aligners: Materials, Biomechanics, and Clinical Application-A Narrative Review.Bioengineering (Basel, Switzerland) · 2026