In Vitro Comparison of Initial and 7-Day System-Level Resultant Forces in Clear Aligners with Different Layer Structures.
Jeong-Hee Seo, Eun-Yeong Park, Jeong-Hyeon Lee, Won-Gi Kim, Sung-Jae Lee, Bongju Kim
Research and Development Center, DENTIS Co., Ltd., Daegu 41065, Republic of Korea. · National Institute of Food and Drug Safety Evaluation, Ministry of Food and Drug Safety, Cheongju 28159, Republic of Korea.
Key points
From the paper's conclusion- These findings do not establish decay-rate differences, material superiority, equivalence, or clinical efficacy.
Abstract
Time-dependent force reduction may affect the biomechanical performance of thermoformed clear aligners. This proof-of-concept in vitro study compared initial and 7-day system-level 3D resultant forces of DURAN, ZENDURA FLX, and MESHEET under attachment-free and attachment-integrated conditions. Thirty independently fabricated aligners (n = 5 per condition) were tested on a rigid resin model with FDI tooth 11 positioned at 5° of labioversion. Forces were recorded at 1 Hz for 168 h under dry room conditions and summarized at 12 h intervals. Temporal series and group-level normalized decay were evaluated descriptively; no longitudinal inferential analysis was performed. Separate 3 × 2 two-way ANOVAs assessed absolute resultant force at 0 and 168 h. Higher endpoint forces were observed under the attachment-integrated condition in this experimental setup at 0 h [F(1,24) = 24.510, p < 0.001, partial η2 = 0.505] and 168 h [F(1,24) = 7.175, p = 0.013, partial η2 = 0.230]. However, because testing followed a fixed, nonrandomized sequence, the observed difference cannot be attributed exclusively to attachment condition. Material and interaction effects were not significant at either endpoint. Under the attachment-integrated condition, normalized decay was 51.4%, 48.2%, and 44.5%, while 168 h mean forces were 1.415, 1.664, and 1.558 N, respectively. These findings do not establish decay-rate differences, material superiority, equivalence, or clinical efficacy.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Initial Force Expression of Different Clear Aligner Systems in a Simulated Maxillary Canine Distalization Model with Lateral Incisor Agenesis: An In Vitro Comparative Study.Bioengineering (Basel, Switzerland) · 2026
- Mechanical properties of thermoformed and direct-printed aligner materials after immersion in 37 °C water: a 14-day in vitro studyScientific Reports · 2026
- Programmed Tooth Movement With and Without Composite Attachments in Clear Aligner Therapy: A Systematic Review of Finite Element Analysis (FEA).Bioengineering (Basel, Switzerland) · 2026
- CLEAR ALIGNER BIOMECHANICS AND PREDICTABILITY: INHERENT MOVEMENT LIMITATIONS AND THE UNMODELLED ROLE OF MATERIAL FORCE DECAYGlobal journal of research in medicine and dentistry · 2026
- Forces and Moments Generated by Thermoforming Aligners and Direct-Printed Aligners: A Systematic Review.Dentistry journal · 2026
- Thirty-Day Thermomechanical Ageing of 3D-Printed and Thermoformed Orthodontic Aligners: A Comparative Force Analysis.International dental journal · 2026