Initial Force Expression of Different Clear Aligner Systems in a Simulated Maxillary Canine Distalization Model with Lateral Incisor Agenesis: An In Vitro Comparative Study.
Alessio Verdecchia, Samuele Avolese, Andrea Tancredi Lugas, Cristina Bignardi, Mara Terzini, Claudia Dettori, Enrico Spinas, Teresa Cobo,
Orthodontics Division, Instituto Asturiano de Odontología, Universidad de Oviedo, 33006 Oviedo, Spain. · Specialization School in Orthodontics, Department of Surgical Sciences, Dental School of the University of Torino, 10129 Torino, Italy.
Key points
From the paper's conclusion- Background: This in vitro study compared initial force release by different clear aligner systems during simulated maxillary canine distalization with lateral incisor agenesis and evaluated attachment effects.
Abstract
BACKGROUND: This in vitro study compared initial force release by different clear aligner systems during simulated maxillary canine distalization with lateral incisor agenesis and evaluated attachment effects. METHODS: Five aligner systems were tested: SmartTrackTM (Invisalign®, Align Technology Inc., Santa Clara, CA, USA), TruGENTM (Spark®, Ormco Corporation, Brea, CA, USA), Essix® (SureSmile®, Dentsply Sirona Inc., Charlotte, NC, USA), MasterControl S (Angel Aligner®, Angelalign Technology Inc., Shanghai, China), and a directly 3D-printed aligner fabricated with TC-85 DAC resin (Graphy®, Graphy Inc., Seoul, Republic of Korea). Ten identical aligners per configuration were tested for 1 h at 37 °C in physiological solution. The ElectroForce® system measured the translational force at the canine's root-level support. Data were analyzed using descriptive statistics and two-way ANOVA. RESULTS: TruGENTM with attachments generated the highest mean force (1.25 N), followed by SmartTrackTM (0.61 N), Essix® (0.42 N), MasterControl S (0.39 N), and TC-85 DAC resin (0.01 N). Without attachments, forces were minimal for all systems. Force decay was observed in groups expressing measurable forces. CONCLUSIONS: Attachments enabled measurable translational force components in thermoformed systems. Force expression differed among systems, while TC-85 DAC resin produced negligible forces with or without attachments under experimental conditions. Further clinical validation is warranted.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- In Vitro Comparison of Initial and 7-Day System-Level Resultant Forces in Clear Aligners with Different Layer Structures.Bioengineering (Basel, Switzerland) · 2026
- Programmed Tooth Movement With and Without Composite Attachments in Clear Aligner Therapy: A Systematic Review of Finite Element Analysis (FEA).Bioengineering (Basel, Switzerland) · 2026
- Comparative Evaluation of Initial Horizontal and Occlusal Forces Generated by Orthodontic Aligners Fabricated with Different Materials.Journal of functional biomaterials · 2026
- Comparison of maxillary arch expansion using clear aligners with and without composite attachments - A finite element study.Bioinformation · 2026
- Direct 3D-Printed Clear Aligners: Materials, Biomechanics, and Clinical Application-A Narrative Review.Bioengineering (Basel, Switzerland) · 2026
- CLEAR ALIGNER BIOMECHANICS AND PREDICTABILITY: INHERENT MOVEMENT LIMITATIONS AND THE UNMODELLED ROLE OF MATERIAL FORCE DECAYGlobal journal of research in medicine and dentistry · 2026