Accuracy of complete-arch implant impressions obtained with intraoral scanning, calibrated intraoral scan protocol, extraoral and intraoral photogrammetry, and conventional impression techniques: An in vitro study.
Jiayi Lu, Jiayi Yu, Ashraf Adi, Berna Saglik, Fei Liu, Junying Li
Department of Biologic and Materials Sciences and Prosthodontics, University of Michigan School of Dentistry, Ann Arbor, Michigan, USA.
Key points
From the paper's conclusion- Extraoral photogrammetry demonstrated the highest overall accuracy, whereas the calibrated intraoral scan protocol and conventional impressions showed smaller distal deviations under constrained alignment conditions.
Abstract
PURPOSE: To compare the accuracy of five techniques for complete-arch implant impressions: conventional open-tray splinted impression technique (CNV), direct intraoral scanning (IOS), calibrated intraoral scan protocol (CISP), extraoral photogrammetry (EPG), and intraoral photogrammetry (IPG). MATERIALS AND METHODS: A maxillary edentulous model with six implants was used. Scan bodies were connected at the abutment level, and desktop scanning (DSK) data served as the reference dataset. Five impression techniques (CNV, IOS, CISP, EPG, IPG) were performed 10 times each. DSK was repeated 10 times and included as a group only for precision evaluation. STL datasets were aligned using two strategies: alignment of all scan bodies to evaluate overall fitness and alignment of the first and second scan bodies to simulate a virtual Sheffield fit test. Linear deviation, angular deviation, and root mean square (RMS) error were calculated to evaluate trueness and precision. Nonparametric statistical tests were applied (α = 0.05). RESULTS: For trueness, when aligned using all scan bodies, EPG demonstrated the highest trueness with the lowest linear deviation (median: 24.40 µm) and angular deviation (median: 0.07°). CISP (median: 38.26 µm) and CNV (median: 39.31 µm) showed comparable linear deviations, both significantly lower than those of IOS (median: 48.37 µm). RMS errors were similar among EPG (median: 19.47 µm), IPG (median: 19.86 µm), and CISP (median: 21.55 µm) and were smaller than those of IOS (median: 27.30 µm). When aligned using SB1 and SB2, linear deviation and RMS error increased toward distal implants in all groups. At SB6, median linear deviations reached 157.82 µm (IOS), 194.13 µm (EPG), and 188.70 µm (IPG), whereas CNV and CISP remained below 100 µm. For precision, EPG showed the highest precision with the lowest linear deviation (median: 7.77 µm), angular deviation (median: 0.02°), and RMS error (median: 4.18 µm), whereas IOS demonstrated the lowest precision (linear deviation: 66.59 µm) using overall fit test. When aligned by SB1 and SB2, EPG showed the highest stability and outperformed the other groups through all scan body sites. CONCLUSION: Extraoral photogrammetry demonstrated the highest overall accuracy, whereas the calibrated intraoral scan protocol and conventional impressions showed smaller distal deviations under constrained alignment conditions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Relative accuracy of intraoral photogrammetry and intraoral scanning with conventional scan-body for full-arch implants.Journal of prosthodontics : official journal of the American College of Prosthodontists · 2026
- Comparative trueness of complete-arch implant position acquisition using auxiliary geometric device-aided and noncalibrated scanbody-based intraoral scanning versus smartphone-based and dedicated extraoral photogrammetry.Journal of prosthodontics : official journal of the American College of Prosthodontists · 2026
- Trueness of extraoral photogrammetry, intraoral photogrammetry and direct intraoral scanning in the full-arch digital implant impression: a comparative in vitro studyJournal of Dentistry · 2025
- Accuracy of complete-arch implant positions recorded by analog impressions, intraoral scanning, and extraoral and intraoral photogrammetry.Journal of prosthodontics : official journal of the American College of Prosthodontists · 2026
- Trueness and Precision of Three Novel Scan Body Designs with Horizontal Extensions for Complete-Arch Implant Impressions: A Comparative In Vitro Study with Intraoral Scanning and Photogrammetry Systems.Journal of functional biomaterials · 2026
- Evaluation of four digital methods in capturing complete-arch implant positions: Direct scanning, splinted scan bodies, three-dimensional-printed scan aids, and intraoral photogrammetry.Journal of prosthodontics : official journal of the American College of Prosthodontists · 2026