Biomechanical Effects of Horizontal, Vertical, and Combined Misfits in Full-Arch Implant-Supported Titanium Frameworks: A Three-Dimensional Finite Element Analysis.
Hale Arikan Kalayci, Mustafa Baris Guncu
Department of Prosthodontics, Faculty of Dentistry, Başkent University, Ankara 06790, Turkey. · Department of Prosthodontics, Faculty of Dentistry, Hacettepe University, Ankara 06100, Turkey.
Key points
From the paper's conclusion- These findings indicate that the types, magnitudes, and locations of misfits should be considered during framework-fit assessments, with particular attention to combined misfits, before definitive seating.
Abstract
This study evaluated the effects of misfit type, magnitude, and location on the stress distribution in full-arch screw-retained implant frameworks. A maxillary finite element model with four implants was analyzed under 16 scenarios, characterized by horizontal misfits of 10, 50, 100, and 200 µm; vertical misfits of 10 and 100 µm; and combined 10-10 and 100-100 µm misfits, each positioned anteriorly or posteriorly. Forced seating was simulated using prescribed displacement; no occlusal load or screw preload was applied. Von Mises stresses were evaluated in the framework, occlusal screws, and implants, and principal stresses were assessed in peri-implant bone. Framework stress increased with horizontal misfit magnitude. When the same numerical misfit value (10 or 100 µm) was applied at the same location under otherwise identical model conditions, vertical misfit produced higher framework stress than horizontal misfit, indicating a direction-dependent response associated with different seating deformation modes. The posterior 100-100 µm combined misfit produced the maximum framework (356 MPa), occlusal screw (193 MPa), and implant (250 MPa) stresses. In contrast, the maximum principal stress peaked at the posterior bone site with the anterior 200 µm horizontal misfit (V0 H200 A; 77 MPa), while the most negative minimum principal stress occurred at the posterior bone site with the posterior 200 µm horizontal misfit (V0 H200 P; -52 MPa). Among the tested scenarios, combined misfits yielded the highest framework and screw stresses, whereas implant and bone responses depended on the magnitude and location of the misfit. These findings indicate that the types, magnitudes, and locations of misfits should be considered during framework-fit assessments, with particular attention to combined misfits, before definitive seating.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Posterior Implant Tilt as an Alternative to Sinus Elevation in Full-Arch Maxillary Rehabilitation: A Comparative Finite Element Analysis.Journal of stomatology, oral and maxillofacial surgery · 2026
- Finite element analysis of stress distribution in zygomatic implant configurations with different hybrid prosthesis superstructure materialsScientific Reports · 2026
- Finite Element Analysis of the Load-Bearing Components of a Stackable Surgical Guide System During Flapless Implant Osteotomy in a Fully Edentulous Maxilla.Materials (Basel, Switzerland) · 2026
- Biomechanical Evaluation of Different Posterior Mandibular Implant Configurations Under Bruxism: An FEA Study.Journal of functional biomaterials · 2026
- Single Versus Double Implants in a Narrowed Mandibular Molar Space: A Finite Element Analysis.Journal of functional biomaterials · 2026
- Biomechanical Interaction Between Endosseous and Patient-Specific Subperiosteal Implants in Full-Arch Rehabilitation of the Atrophic Maxilla: A Finite Element Analysis.The International journal of oral & maxillofacial implants · 2026