Single Versus Double Implants in a Narrowed Mandibular Molar Space: A Finite Element Analysis.
Elif Aktürk, Melis Banri, Gülsüm Sayın Özel
Department of Prosthodontics, Institute of Health Sciences, Istanbul Medipol University, Beykoz, 34815 Istanbul, Türkiye. · Department of Prosthodontics, Faculty of Dentistry, Istanbul Medipol University, Beykoz, 34815 Istanbul, Türkiye.
Key points
From the paper's conclusion- A mandibular model was constructed by computer-aided design; ridge resorption and mesial tipping of the second molar left a 13.6 mm mesiodistal space and a 7.5 mm crestal ridge width.
Abstract
After molar loss, tipping of the adjacent teeth and extrusion of the opposing tooth often leave a mesiodistal space too narrow for a conventional implant. This study compared stress in the implant components and peri-implant bone among single- and double-implant configurations of different diameters in such a space. A mandibular model was constructed by computer-aided design; ridge resorption and mesial tipping of the second molar left a 13.6 mm mesiodistal space and a 7.5 mm crestal ridge width. Four configurations were modeled: 4.8 mm single (M1), 4.1 mm single (M2), 3.3 + 3.3 mm double (M3), and 4.1 + 3.3 mm double (M4). Vertical (150 N) and oblique (300 N at 45°) loads were applied; von Mises stress in the components and maximum and minimum principal stresses in bone were recorded. Oblique loading raised stress in every structure; because the oblique load was twice the vertical load, part of this increase reflects the higher force rather than loading direction alone, and direction-related increases (normalized per unit load) ranged from approximately 2- to 9-fold across components and bone. Under vertical loading, M1 gave the lowest implant body, abutment, and screw stresses (31.0, 36.7, and 16.1 MPa). Under oblique loading, M4 lowered implant body and abutment stress, whereas M1 retained the lowest screw (192.0 MPa) and configuration-level bone stresses (31.2 and 7.2 MPa). Because screw preload was not modeled, screw-stress comparisons should be interpreted as relative mechanical demand rather than as predictors of loosening or fracture risk. No configuration minimized stress in every structure. Implant diameter, site, component, and loading condition should be weighed together.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Biomechanical Comparison of All-on-Four and Interforaminal All-on-Six Concepts Using Titanium and Ti-Zr (Roxolid®): A Nonlinear Finite Element Study.Journal of stomatology, oral and maxillofacial surgery · 2026
- Influence of all-on-4 implant angles on stability and crestal bone - A finite element optimization analysis.Journal of dental sciences · 2026
- Biomechanical Evaluation of Different Posterior Mandibular Implant Configurations Under Bruxism: An FEA Study.Journal of functional biomaterials · 2026
- Bite Force Analysis Using Numerical Simulation with Different Prosthesis Anchorages.Biomimetics (Basel, Switzerland) · 2026
- Biomechanical Comparative Evaluation of the Atrophic Edentulous Mandible Using All-on-4, All-on-5 and All-on-6 Concepts: A Finite Element Analysis.Dentistry journal · 2026
- Retrospective CBCT-based anatomical assessment of mandibular first and second molars: a cross-sectional study with potential implications for immediate implant planning.The Saudi dental journal · 2026