Journal of Clinical Medicine

Infection and Retrieval of Leadless Pacemakers: Current Challenges and Future Directions

Ibrahim Antoun, Alkassem Alkhayer, Fahad Muhammad, Omar Farooq, Eyad Jamileh, Rajesh Chelliah, Giovanni Mariscalco, Mustafa Zakkar

Review

Key points

From the paper's conclusion
  • This narrative review examines the mechanisms underlying the lower infection risk of leadless pacemakers, reported infections and their microbiology, diagnostic and management strategies, and current retrieval techniques.

Abstract

Leadless pacemakers were developed to reduce the risk of infection associated with conventional pacing systems by eliminating the subcutaneous generator pocket and transvenous leads. Over the past decade, clinical studies, including five-year follow-up data, have shown low absolute infection rates and favourable complication and revision profiles relative to conventional pacemakers. Their use has also expanded to atrial and dual-chamber pacing, and they are increasingly used following the removal of infected transvenous systems. However, important challenges remain. Although uncommon, leadless pacemaker infections have been reported, including cases of bacteraemia and infective endocarditis involving newer atrial and helix-fixation devices. Diagnosis can be difficult because there are no visible pocket-related signs of infection. Management is also unsettled. In the Micra investigational study all systemic infectious events were adjudicated as unrelated to the device or procedure, so they do not demonstrate that device-related bacteraemia can be treated without extraction, and no comparative evidence defines the balance between device removal and retention. Device retrieval presents another challenge, particularly after prolonged implantation, when tissue encapsulation can make extraction more difficult and increase procedural risks. Reports of atrial device embolisation have raised further concerns about retrieval techniques. This narrative review examines the mechanisms underlying the lower infection risk of leadless pacemakers, reported infections and their microbiology, diagnostic and management strategies, and current retrieval techniques. It also discusses the role of leadless pacing following extraction of infected conventional systems and highlights areas where further research is needed, particularly with the increasing use of atrial and dual-chamber devices.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Infection and Retrieval of Leadless Pacemakers: Current Challenges and Future Directions — Science Skim