Key points
From the paper's conclusion- This narrative review examines the mechanisms underlying the lower infection risk of leadless pacemakers, reported infections and their microbiology, diagnostic and management strategies, and current retrieval techniques.
Abstract
Leadless pacemakers were developed to reduce the risk of infection associated with conventional pacing systems by eliminating the subcutaneous generator pocket and transvenous leads. Over the past decade, clinical studies, including five-year follow-up data, have shown low absolute infection rates and favourable complication and revision profiles relative to conventional pacemakers. Their use has also expanded to atrial and dual-chamber pacing, and they are increasingly used following the removal of infected transvenous systems. However, important challenges remain. Although uncommon, leadless pacemaker infections have been reported, including cases of bacteraemia and infective endocarditis involving newer atrial and helix-fixation devices. Diagnosis can be difficult because there are no visible pocket-related signs of infection. Management is also unsettled. In the Micra investigational study all systemic infectious events were adjudicated as unrelated to the device or procedure, so they do not demonstrate that device-related bacteraemia can be treated without extraction, and no comparative evidence defines the balance between device removal and retention. Device retrieval presents another challenge, particularly after prolonged implantation, when tissue encapsulation can make extraction more difficult and increase procedural risks. Reports of atrial device embolisation have raised further concerns about retrieval techniques. This narrative review examines the mechanisms underlying the lower infection risk of leadless pacemakers, reported infections and their microbiology, diagnostic and management strategies, and current retrieval techniques. It also discusses the role of leadless pacing following extraction of infected conventional systems and highlights areas where further research is needed, particularly with the increasing use of atrial and dual-chamber devices.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Concomitant Aveir AR and Micra AV2 Hybrid Leadless Implantation During Infected Pacemaker Extraction.Pacing and clinical electrophysiology : PACE · 2026
- Transvenous leadless pacemaker extraction: When, who, where, and how?Kardiologia Polska · 2026
- A decade of leadless pacemaker implantation: technical performance, safety and device longevityEuropean Heart Journal · 2026
- Ten years follow-up data on a leadless pacing system – real life experience in comparison to data of the prospective trialEuropean Heart Journal · 2026
- Procedural Outcomes of Leadless Pacemaker Extraction and Retrieval: A Systematic Review and Meta-Analysis With Descriptive Synthesis of Post-Implant Management.Journal of cardiovascular electrophysiology · 2026
- Lose the Hardware: The Rise of Leadless Modular Cardiac Pacing.Journal of clinical medicine · 2026