A decade of leadless pacemaker implantation: technical performance, safety and device longevity

J Certo Pereira, M Domingues, F Moscoso Costa, D A Gomes, S Fartouce, G Rodrigues, D Matos, J Carmo,

Key points

From the paper's conclusion
  • We report a 10-year single-center experience focusing on procedural practice evolution, long-term pacing parameters, safety and battery longevity.

Abstract

Background Leadless pacemakers (L-PM) eliminate the need for transvenous leads and pacemaker pockets, reducing lead-related complications. After more than a decade of clinical use worldwide, real-world data on long-term performance and management of end-of-life devices remain limited. We report a 10-year single-center experience focusing on procedural practice evolution, long-term pacing parameters, safety and battery longevity. Methods Single-center prospective registry including all consecutive patients undergoing ventricular L-PM implantation from May 2015 to November 2025. Clinical characteristics, procedural data, pacing parameters and estimated battery longevity were collected at implant and at latest follow-up (FUP). Results The cohort included 447 patients (mean age 80.0±9.4 years; 64% male). Successful implantation occurred in 445 patients (99.6%). Main pacing indications were high-grade AV block (64%) and atrial fibrillation with pauses (27%). Notably, 8% of implants were performed after extraction of an infected conventional system and 17% following transcatheter structural heart procedures. Procedural efficiency improved over the years, with global mean procedure and fluoroscopy times of 41.1±24.7 min and 4.4±3.8 min. Acute major complications were infrequent: pericardial effusion occurred in 0.9% (one tamponade), and 0.4% required conversion to a transvenous pacemaker (one due to acute L-PM dysfunction and the other due to a small RV cavity). Additionally, two lymphatic access-site complications were reported, one requiring surgical treatment. No device dislodgment occurred. During a mean FUP of 2.5 ± 2.3 years, pacing parameters remained stable (threshold: 0.64 to 0.60V; R-wave amplitude: 12.3 to 12.5mV). Mean ventricular pacing was 59±39% and estimated battery longevity was >8 years in 84%. Among those with >5-year of FUP (N=60; mean FUP 6.7±2.4 years), 80% maintained >5 years of predicted longevity. Three upgrades to CRT or LBBAP occurred due to pacing-induced LV dysfunction. One true end-of-life event occurred 6 years post-implant (100% VP, high thresholds), successfully managed with a second L-PM. There were 119 deaths (27%), none device-related. Conclusion Over 10 years of experience, L-PM implantation proved to be a robust and safe pacing modality in routine practice, maintaining stable electrical performance and excellent battery durability, with only one device reaching end-of-life. Ongoing FUP will clarify long-term replacement strategies and lifetime device management in this growing population.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

A decade of leadless pacemaker implantation: technical performance, safety and device longevity — Science Skim