Snare-Free Endoscopic Tricuspid Valve Repair Using a Percutaneous Venous Self-Expanding Cannula: A Descriptive Cohort Study.
Robert Balan, Parwis Massoudy, Marius Mihai Harpa, Klara Brînzaniuc, Jonah Schwarz
Doctoral School, George Emil Palade University of Medicine, Pharmacy, Science and Technology of Targu Mures, 540142 Targu Mures, Romania. · Department of Cardiac Surgery, Klinikum Passau, 94032 Passau, Germany.
Key points
From the paper's conclusion- Conclusion: Snare-free totally endoscopic tricuspid valve repair using percutaneous self-expanding venous cannulation appeared technically feasible and was associated with acceptable early clinical outcomes in this selected single-center cohort.
Abstract
Background: Minimally invasive and endoscopic techniques have expanded the surgical options for tricuspid valve repair. Conventional approaches often require manual snaring of the venae cavae, which can increase procedural complexity, especially in advanced heart failure settings. This study describes a snare-free totally endoscopic approach to tricuspid valve repair utilizing percutaneous venous self-expanding cannulation. Methods: Between 2020 and 2025, 32 patients with severe tricuspid regurgitation (TR) underwent totally endoscopic tricuspid valve repair using a standardized snare-free technique. Venous drainage was achieved via predominantly percutaneous femoral cannulation with a self-expanding venous cannula, providing central venous decompression without external tourniquets or loops. All clinical, intraoperative, and early postoperative parameters were collected and analyzed using descriptive statistical methodology. Results: Snare-free cannulation was performed in all 32 patients (100.0%, 95% CI: 89.1-100.0%). Pure snare-free endoscopic repair was completed in 31 patients (96.9%, 95% CI: 83.8-99.9%), with one patient (3.1%) requiring conversion to full median sternotomy and manual caval snaring. The mean cardiopulmonary bypass (CPB) time was 145.9 ± 35.8 min, and the mean aortic cross-clamp duration was 92.4 ± 24.5 min. All-cause 30-day mortality was 3.1% (n = 1/32), and no cases of clinically documented hemolysis were observed (0.0%, 95% CI: 0.0-10.9%). The mean intensive care unit stay was 6.0 ± 4.9 days (n = 31), and the mean postoperative hospital length of stay was 15.3 ± 9.6 days (n = 30). Quantitative predischarge residual TR grades and transvalvular gradients were not systematically recorded; therefore, endoscopic completion in this cohort establishes cannulation feasibility rather than definitive valve-repair efficacy. Conclusion: Snare-free totally endoscopic tricuspid valve repair using percutaneous self-expanding venous cannulation appeared technically feasible and was associated with acceptable early clinical outcomes in this selected single-center cohort.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Outcomes of tricuspid transcatheter edge-to-edge repair in patients with cardiac implantable electronic devices: a systematic review and meta-analysisEuropean Heart Journal · 2026
- Totally endoscopic beating-heart redo tricuspid valve replacement using a frame-preserving strategy: a case report.International journal of surgery case reports · 2026
- Standardized totally endoscopic non-robotic mitral valve repair for degenerative mitral regurgitation: early single-center outcomes in 84 patients.Global cardiology science & practice · 2026
- Tricuspid Transcatheter Edge-to-Edge Repair in Patients with Transvalvular Cardiac Implantable Electronic Device Leads: A Systematic Review and Meta-Analysis.The American journal of cardiology · 2026
- Transcatheter bi-caval valve implantation in a post-pacemaker patient with severe tricuspid regurgitation: A case report.Journal of cardiology cases · 2026
- Tricuspid Valve Transcatheter Edge-to-Edge Repair in Patients With Cardiac Implantable Electronic DevicesJACC: Cardiovascular Interventions · 2025