Outcomes of tricuspid transcatheter edge-to-edge repair in patients with cardiac implantable electronic devices: a systematic review and meta-analysis
M Cheikh Ibrahim, K I N A N Alabboud, H Almesto Alabdullh, N A Z I R Adel, V Bittar De Pontes, A Lauten
Key points
From the paper's conclusion- Background Transvenous cardiac implantable electronic device (CIED) leads across the tricuspid valve may present anatomical challenges for transcatheter edge-to-edge repair (T-TEER).
Abstract
Background Transvenous cardiac implantable electronic device (CIED) leads across the tricuspid valve may present anatomical challenges for transcatheter edge-to-edge repair (T-TEER). However, the safety and efficacy of T-TEER in these patients are unclear. Methods We conducted a systematic search of PubMed, Embase, and Cochrane Library from inception through November 2025 for studies comparing T-TEER in patients with versus without transvalvular CIED leads. Pooled risk ratios (RR) with 95% confidence intervals (CI) were calculated using a random-effects model. Results Six studies comprising 4,891 patients (1,240 with and 3,651 without CIEDs) were included. Procedural success was comparable between the two groups (RR 1.00, 95% CI 0.98–1.02, p=0.96; I2=0%). At discharge, successful TR reduction (≤ 2) was similarly achieved in both cohorts (RR 0.99, 95% CI 0.94–1.04, p=0.60; I2=0%), with results remaining comparable for sustained TR ≤ 2 (RR 0.96, 95% CI 0.90–1.02, p=0.20; I2=0%) and functional improvement to NYHA class ≤ II (RR 0.95, 95% CI 0.89–1.01, p=0.12; I2=0%) at mid-term follow-up. CIED presence was not statistically associated with an increased risk of all-cause mortality, cardiovascular mortality, heart failure-related hospitalization, or tricuspid reintervention. Conclusion In this meta-analysis, procedural success, sustained TR reduction, and mid-term clinical outcomes were similar between patients undergoing T-TEER with and without CIEDS leads, supporting T-TEER as a feasible and safe option in selected patients.Graphical Abstractprevalence of TI regurgitation severity
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Tricuspid Transcatheter Edge-to-Edge Repair in Patients with Transvalvular Cardiac Implantable Electronic Device Leads: A Systematic Review and Meta-Analysis.The American journal of cardiology · 2026
- Tricuspid Valve Transcatheter Edge-to-Edge Repair in Patients With Cardiac Implantable Electronic DevicesJACC: Cardiovascular Interventions · 2025
- Transcatheter tricuspid valve interventions in patients with cardiac implantable electronic devices: a systematic review and meta-analysisEuropean Heart Journal · 2026
- The Impact of Preexisting Cardiac Implantable Electronic Devices on the Safety of Transcatheter Tricuspid Valve Interventions: A Systematic Review and Meta-Analysis.Journal of cardiovascular development and disease · 2026
- TricValve system implantation in patients with cardiac implantable electronic devices: A multicentre observational study.European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery · 2026
- Functional, echocardiographic outcomes and complications after Transcatheter Tricuspid Edge-to-Edge Repair (T-TEER): a systematic review and meta-analysisEuropean Heart Journal · 2026