Standardized totally endoscopic non-robotic mitral valve repair for degenerative mitral regurgitation: early single-center outcomes in 84 patients.
Phan Quang Thuan, Pham Tran Viet Chuong, Cao Dang Khang, Nguyen Hoang Dinh
Department of Cardiovascular Surgery, University Medical Center, University of Medicine and Pharmacy at Ho Chi Minh City, Ho Chi Minh City, Viet Nam.
Key points
From the paper's conclusion- Conclusions: Standardized totally endoscopic non-robotic mitral valve repair using the DCT approach was feasible and reproducible, achieving a 100% repair rate with favorable early outcomes.
Abstract
Objective: To evaluate early clinical and echocardiographic outcomes of totally endoscopic, non-robotic mitral valve repair for degenerative mitral regurgitation using a standardized DCT approach (double-port; camera and main working port in the same intercostal space; skin incision <3 cm), and to propose operational criteria for "totally endoscopic" mitral surgery. Methods: In this single-center observational study, 84 consecutive patients with severe degenerative mitral regurgitation meeting 2021 ESC/EACTS surgical criteria underwent totally endoscopic non-robotic repair with three-dimensional visualization between July 2023 and January 2026. The technique used a primary skin incision ≤3 cm with no rib spreading in all cases. Clinical and echocardiographic outcomes within 30 days were assessed. Results: Repair was successful in all 84 patients (100%), without conversion to sternotomy or replacement. All underwent ring annuloplasty; neochordal implantation was performed in 69 (82.1%). Mean incision length was 2.9 ± 0.3 cm. Mean cardiopulmonary bypass and cross-clamp times were 163.3 ± 50.5 and 112.1 ± 37.5 minutes, respectively. There was no 30-day mortality. Major complications each occurred in 1 patient (1.2%): re-exploration for bleeding, intracranial hemorrhage, and femoral artery occlusion. Median intensive care unit and hospital stays were 2 (IQR 2-3) and 10 (IQR 9-14) days. Echocardiography showed no residual regurgitation ≥ moderate and preserved ventricular function in all patients. Conclusions: Standardized totally endoscopic non-robotic mitral valve repair using the DCT approach was feasible and reproducible, achieving a 100% repair rate with favorable early outcomes. Given the single-center design and short follow-up, these should be interpreted as feasibility data.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Double-Port Totally Endoscopic Mitral Valve Replacement Through a Prosthesis-Sized Working Incision with Posterior Subvalvular Preservation.Journal of the Saudi Heart Association · 2026
- Early Outcomes of 2-Port Totally Endoscopic Mitral Valve Repair with Artificial Chordae for Degenerative Mitral Regurgitation: A Single-Center Experience.Journal of chest surgery · 2026
- Comparative outcomes of totally endoscopic versus direct vision mini-thoracotomy mitral valve repair: A propensity score-matched retrospective analysis.JTCVS open · 2026
- Single-Port Robotic Mitral Valve Repair: First-in-Human Technique and 30-Day Outcome.JACC. Case reports · 2026
- Totally endoscopic mitral valve replacement: reasons for non-feasibility of repair and 5-year outcomes.Frontiers in cardiovascular medicine · 2026
- Avoiding Resternotomy: Minimally Invasive Redo Mitral Valve Surgery in a Two-Center Series.Journal of clinical medicine · 2026