Effects of Ambulatory Blood Pressure Monitoring During Polysomnography on Sleep Indices and EEG Power.
Jeonghoon Kim, Donghun Kang, Jongshill Lee, Junhee Han, Jeyeon Lee, Myung-Kyu Yi, Byung Sik Kim, Hyun-Jin Kim,
Department of Electronic Engineering, Hanyang University, Seoul 04763, Republic of Korea. · Department of Biomedical Engineering, Hanyang University, Seoul 04763, Republic of Korea.
Key points
From the paper's conclusion- Background/Objectives: Ambulatory blood pressure monitoring (ABPM) may disturb sleep during polysomnography (PSG), and the first-night effect (FNE) can complicate interpretation.
Abstract
Background/Objectives: Ambulatory blood pressure monitoring (ABPM) may disturb sleep during polysomnography (PSG), and the first-night effect (FNE) can complicate interpretation. We evaluated changes associated with ABPM and FNE across whole nights and individual measurements. Methods: This secondary analysis included 72 nominally healthy adults in a balanced two-night crossover, with ABPM on one randomly assigned night. Linear mixed-effects models estimated associations with PSG-derived sleep indices, a composite sleep quality index (SQI), and relative electroencephalographic (EEG) power. Analyses of individual measurements summarized EEG changes, sleep-stage transitions, and automated arousal detections. Benjamini-Hochberg false discovery rate (BH-FDR) adjustment was applied within defined analysis families. Results: FNE and ABPM were associated with lower SQI (β = -0.049 and -0.051, respectively; both BH-adjusted p = 0.028). FNE was associated with altered sleep continuity and architecture, whereas ABPM was associated with higher light-sleep and lower N3-sleep percentages and higher whole-night relative theta power. In the Night 2 paired analysis, relative delta power was lower and relative alpha, beta, and gamma power were higher during ABPM than before ABPM (all BH-adjusted p < 0.01); the theta difference did not reach significance (BH-adjusted p = 0.0632). Of 655 eligible ABPM measurements beginning during sleep, 395 (60.3%) contained at least one arousal detection within the 2 min measurement window. Conclusions: These detections indicate temporal co-occurrence and do not establish that cuff inflation caused arousal. Concurrent ABPM and study-night order should be considered when interpreting PSG. An adaptation PSG night may be considered when feasible, as may cuffless blood pressure monitoring once its accuracy has been established for the intended setting.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Event-level nocturnal blood pressure dynamics in obstructive sleep apnea assessed by cuffless monitoringSLEEP · 2026
- Revisiting the First Night Effect of Polysomnography Using Wearable EEG Headbands in Older Adults with Sleep DisturbancesmedRxiv · 2026
- Participant experience with the SpaceLabs 90227 ambulatory blood pressure monitor and SOMNOmedics ABPMpro device.Blood pressure monitoring · 2026
- Cardiac Autonomic Association Atlas of Sleep Parameters in Obstructive Sleep Apnea: A Large-Scale Cohort-Based Observational Study.Sleep · 2026
- Exploratory analysis of electroencephalogram activity preceding nocturnal enuresis episodes using home-based sleep monitoring.Sleep & breathing = Schlaf & Atmung · 2026
- Revisiting the concept that interictal implies asymptomatic: Pulse wave amplitude drops uncover autonomic responses during generalized paroxysmal fast activities.Epilepsia · 2026