Revisiting the First Night Effect of Polysomnography Using Wearable EEG Headbands in Older Adults with Sleep Disturbances
A. Chen, G. Cho, I. Murphy, M. Asamoah-Mensah, J. Talarczyk, B. Miner
Key points
From the paper's conclusion- Conclusions: In older adults with sleep disturbances, a single night of HPSG was associated with greater wake after sleep onset, less N3 sleep, and lower sleep efficiency than other nights measured with wearable EEG, suggesting that one-night PSG may overstate sleep disruption and understate deep sleep.
Abstract
Study Objectives: The first night effect (FNE), where sleep is altered during the first night of polysomnography (PSG), may affect the validity of single-night PSG assessments, yet its magnitude relative to habitual sleep is difficult to characterize using repeated PSG alone. We examined FNE during home-based PSG (HPSG) in older adults with sleep disturbances using multi-night wearable EEG headband (HB) recordings. Methods: Fifty-eight community-dwelling adults aged 55-85 years with sleep disturbances completed up to seven nights of HB monitoring, including one night of simultaneous HPSG. Using HB-derived measures, we compared total sleep time (TST), wake after sleep onset (WASO), sleep efficiency (SE), minutes in N3 sleep, and minutes in REM sleep between HPSG and non-HPSG nights via pairwise comparisons and linear mixed-effects models adjusting for age, sex, and race/ethnicity. Results: Sleep differed significantly between HPSG and non-HPSG nights, with roughly 35 minutes longer WASO, 21 minutes less N3 sleep, and 15% lower SE (ps < .001) during HPSG nights. TST and REM sleep did not differ between HPSG and non-HPSG nights. Findings were consistent when separately comparing nights preceding and following HPSG. Conclusions: In older adults with sleep disturbances, a single night of HPSG was associated with greater wake after sleep onset, less N3 sleep, and lower sleep efficiency than other nights measured with wearable EEG, suggesting that one-night PSG may overstate sleep disruption and understate deep sleep. Multi-night wearable EEG monitoring may help assess the representativeness of single-night PSG measurements, thereby improving the accuracy of sleep measurement interpretation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Effects of Ambulatory Blood Pressure Monitoring During Polysomnography on Sleep Indices and EEG Power.Journal of clinical medicine · 2026
- Performance evaluation of consumer sleep-tracking wearables and nearables in healthy young and older adultsSLEEP Advances · 2026
- WakeSentry: real-time awakening detection from single-channel EEG across sleep cohorts and forehead headbandsmedRxiv · 2026
- Exploratory analysis of electroencephalogram activity preceding nocturnal enuresis episodes using home-based sleep monitoring.Sleep & breathing = Schlaf & Atmung · 2026
- Characterization of Sleep, Spectral, and Epileptiform Activity in Individuals Aged 8-27 Years with SYNGAP1-Related Disorder Using an at-Home Dry EEG HeadbandmedRxiv · 2026
- AnySleep: a channel-agnostic deep learning system for high-resolution sleep staging in multi-center cohorts.NPJ digital medicine · 2026