The Cusp-Overlap Technique Versus the Standard Three-Cusp Technique for Self-Expanding Transcatheter Aortic Valves-A Single-Center Experience.
Alexandru Ispas, Damien Brunet, Redouane Saady, Yacoub Habib, Catalin Pestrea, Laurent Drogoul
Department of Cardiology, Monaco Cardiothoracic Center, 98000 Monaco-Ville, Monaco. · Department of Cardiology, Brașov Regional Emergency Hospital, 500024 Brașov, Romania.
Key points
From the paper's conclusion- Conclusions: In this real-world single-center cohort, the cusp-overlap technique was not associated with a statistically significant reduction in PPMI after TAVR with the CoreValve Evolut™ SE-THV.
Abstract
Background: Conduction disturbances and the subsequent need for permanent pacemaker implantation (PPMI) remain a major limitation of transcatheter aortic valve replacement (TAVR) with self-expanding transcatheter heart valves (SE-THVs). The cusp-overlap technique (COT) has been proposed to optimize implantation depth and reduce PPMI rates compared to the standard three-cusp technique (3CT). Methods: This retrospective, single-center study included 113 consecutive patients with symptomatic severe aortic stenosis who underwent TAVR with the Medtronic CoreValve Evolut™ SE-THV(Medtronic, Minneapolis, MN, USA) between September 2020 and March 2023. Patients were treated using either COT (n = 49) or 3CT (n = 62). Baseline characteristics, procedural outcomes, and 30-day clinical events were compared before and after one-to-one propensity score matching. The primary endpoint was the incidence of PPMI at hospital discharge; the secondary endpoint was a composite of death, stroke, life-threatening or disabling bleeding, major vascular complications, and moderate/severe paravalvular regurgitation at 30 days. A post hoc power calculation was performed given the low observed event rate. Results: Procedural success was achieved in 98.2% of patients. In the unmatched cohort, PPMI occurred in 6.1% (COT) vs. 9.7% (3CT) (p = 0.48). In the matched cohort (49 pairs), PPMI rates were 6.1% (COT) vs. 12.2% (3CT) (p = 0.48). With only 3 vs. 6 PPMI events in the matched cohort, the study had an estimated post hoc power of approximately 19% (two-sided α = 0.05) to detect the observed difference, so the negative primary result should be regarded as inconclusive rather than as evidence of equivalence between techniques. The secondary composite endpoint occurred less frequently in the COT group both before matching (14.3% vs. 32.3%; p = 0.049) and after matching (14.3% vs. 30.6%, p = 0.049). This composite difference was driven predominantly by the moderate/severe paravalvular regurgitation (PVL) component (12.2% vs. 24.2% unmatched; 12.2% vs. 22.4% matched) rather than by death, stroke, or major vascular complications. Evolut device generation differed markedly by arm (COT patients received later-generation devices far more often than 3CT; p < 0.001), and is presented in the Methods/Results Sections as a key temporal confounder. COT was associated with a lower incidence of moderate/severe paravalvular regurgitation, without prolonging procedural time. Conclusions: In this real-world single-center cohort, the cusp-overlap technique was not associated with a statistically significant reduction in PPMI after TAVR with the CoreValve Evolut™ SE-THV. COT was, however, associated with fewer paravalvular leaks and a lower rate of the secondary composite of adverse clinical events at 30 days.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Avoid It or Reach It? The Cardiac Conduction Axis as a Common yet Divergent Determinant of Patient Outcomes in Transcatheter Aortic Valve Replacement and Conduction-System Pacing.Heart rhythm · 2026
- Comparative electrophysiology of aortic root pacing in humansEuropean Heart Journal · 2026
- 1-year outcomes after conduction system pacing after transcatheter aortic valve implantationEuropean Heart Journal · 2026
- Multimodal CT-echocardiographic score for preprocedural prediction of permanent pacemaker implantation after transcatheter aortic valve replacementEuropean Heart Journal · 2026
- Conduction disturbance recovery and permanent pacing requirement in bicuspid aortic valves post-TAVR.Cardiovascular revascularization medicine : including molecular interventions · 2026
- Short-frame, self-expanding, fully recapturable transcatheter aortic valve replacement device in pure aortic regurgitation: Procedural performance and 30-day outcomes.Cardiovascular revascularization medicine : including molecular interventions · 2026