Comparative electrophysiology of aortic root pacing in humans
I Karpenko, A Ardashev, J Wasserlauf, E Zhelyakov, D Aksenov, O Yatsenko, D Volkov
Key points
From the paper's conclusion- Conclusions Among paravalvular aortic root sites, pacing adjacent to the left-sided His bundle uniquely combined universal ventricular capture, lower capture thresholds, and narrower paced QRS duration, distinguishing it from coronary cusp pacing, which was feasible but required higher outputs and produced less synchronous ventricular activation.
Abstract
Background Millimeter-scale pacemakers integrated into transcatheter aortic valve (TAVR) platforms are emerging as a potential solution for post-valve conduction disease. Their development, however, is limited by the lack of in vivo human data defining where reliable myocardial capture can be achieved from the paravalvular aortic root and at what electrical cost. Objective To compare the feasibility and electrophysiologic characteristics of transaortic pacing from the right coronary cusp (RCC), left coronary cusp (LCC), non-coronary cusp (NCC), and the left-sided His bundle (LV His) region, and to translate these findings into design constraints for valve-integrated and ultra-miniaturized pacing systems. Methods In 25 consecutive patients undergoing clinically indicated left-sided electrophysiology procedures, sequential bipolar pacing was performed via a retrograde transaortic approach at the RCC, LCC, NCC, and LV His region following completion of the index procedure. Pacing sites were localized using 3D electroanatomic mapping, biplane fluoroscopy, and intracardiac echocardiography. Capture thresholds (1 ms pulse width), local electrogram amplitudes, and paced QRS duration and morphology were quantified. Results Ventricular capture was universal at the LV His region (25/25, 100%), frequent at the RCC (23/25, 92%) and LCC (19/25, 76%), and absent at the NCC (0/25, 0%), where atrial capture occurred in 8/25 (32%). LV His pacing demonstrated markedly lower capture thresholds (4.6 ± 2.1 mA) and the narrowest paced QRS duration (137.5 ± 15.6 ms), most often with an RBBB-like morphology in V1. In contrast, coronary cusp pacing required significantly higher outputs (RCC 13.3 ± 5.1 mA; LCC 14.2 ± 4.7 mA) and produced wider QRS complexes (≈165 ms). Conclusions Among paravalvular aortic root sites, pacing adjacent to the left-sided His bundle uniquely combined universal ventricular capture, lower capture thresholds, and narrower paced QRS duration, distinguishing it from coronary cusp pacing, which was feasible but required higher outputs and produced less synchronous ventricular activation. The non-coronary cusp demonstrated no ventricular capture but showed atrial excitability, suggesting a distinct dual-chamber electrophysiologic niche.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Pacing during TAVR through a coronary wire in the coronary artery and left ventricular wire.Frontiers in cardiovascular medicine · 2026
- Avoid It or Reach It? The Cardiac Conduction Axis as a Common yet Divergent Determinant of Patient Outcomes in Transcatheter Aortic Valve Replacement and Conduction-System Pacing.Heart rhythm · 2026
- Outcomes of left ventricular pacing with a pre-shaped guidewire during transcatheter aortic valve implantation.REC, interventional cardiology · 2026
- The Cusp-Overlap Technique Versus the Standard Three-Cusp Technique for Self-Expanding Transcatheter Aortic Valves-A Single-Center Experience.Journal of clinical medicine · 2026
- Multimodal CT-echocardiographic score for preprocedural prediction of permanent pacemaker implantation after transcatheter aortic valve replacementEuropean Heart Journal · 2026
- Mechanisms Underlying Alterations in Cardiac Conduction After Transcatheter Aortic Valve ReplacementJAMA Cardiology · 2025