Immediate Loading of 5.2-mm Ultra-Short Implants Supporting Maxillary Overdentures in the Severely Atrophic Maxilla: A Prospective Pilot Study.
Pieter-Jan Boderé, Wout Scharff, Cyrille France, Stefan Vandeweghe, Hugo De Bruyn, Renaat Coopman, Luc Van Doorne
Department of Reconstructive Dentistry, Faculty of Medicine and Health Sciences, Ghent University Hospital, Corneel Heymanslaan 10, 9000 Ghent, Belgium. · Department of Oral Health Sciences, Faculty of Medicine and Health Sciences, Ghent University Hospital, Corneel Heymanslaan 10, 9000 Ghent, Belgium.
Key points
From the paper's conclusion- Conclusions: This prospective pilot study demonstrates the feasibility of an immediately loaded treatment concept using 5.2-mm ultra-short implants splinted with a patient-specific CAD/CAM inter-implant bar (VD CLIC BAR®) to support maxillary overdentures in patients with severe maxillary atrophy.
Abstract
Background: Severe maxillary atrophy often precludes placement of conventional dental implants and frequently requires invasive bone augmentation procedures. This prospective pilot study evaluated a treatment concept using immediately loaded 5.2-mm ultra-short implants connected by a patient-specific CAD/CAM inter-implant bar system (VD CLIC BAR®) to support maxillary overdentures. Methods: Thirteen completely edentulous patients with severe maxillary atrophy (Cawood-Howell Class V or VI) were treated with six to eight immediately loaded 5.2-mm ultra-short implants connected by a patient-specific CAD/CAM inter-implant bar (VD CLIC BAR®) supporting a maxillary overdenture. The primary outcome was implant survival. Secondary outcomes included oral health-related quality of life (OHIP-14), self-reported chewing ability (VAS), implant stability (Periotest), and prosthetic rehabilitation. Results: A total of 96 initial implants and 8 additional implants were placed following early implant failures. The primary implant survival rate after two years was 83.3%. Implant failures occurred predominantly during early healing and were unevenly distributed across the cohort. Early failures were managed by placement of additional ultra-short implants, enabling definitive implant-supported rehabilitation in all patients. Periotest values demonstrated a significant increase in implant stability over time (p < 0.001). Median OHIP-14 scores improved from 32.0 (IQR 20.0-44.0) at baseline to 4.0 (IQR 1.0-20.0) at two years (p = 0.006). Median chewing ability at two years was 82.7 (IQR 50.1-91.9). Conclusions: This prospective pilot study demonstrates the feasibility of an immediately loaded treatment concept using 5.2-mm ultra-short implants splinted with a patient-specific CAD/CAM inter-implant bar (VD CLIC BAR®) to support maxillary overdentures in patients with severe maxillary atrophy. Although early implant failures occurred and required placement of additional ultra-short implants in some patients, all patients ultimately achieved functional implant-supported rehabilitation. These preliminary findings require confirmation in larger controlled studies with longer follow-up.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Retaining Complete Overdentures With Immediately Loaded One-Piece Mini-Implants: A 24-Month Prospective Clinical Study.Clinical implant dentistry and related research · 2026
- Maxillary Bar Overdenture on Immediately Placed Implants: A Clinical Case Report.Case reports in dentistry · 2026
- Surgical Management of Severe Maxillary Atrophy Using Customized Subperiosteal Titanium Implants: Report of Two Clinical Cases With 42 Months of Follow-Up.Case reports in dentistry · 2026
- A 4-mm-Short Implant Rehabilitation in the Posterior Maxilla With Dynamic Navigation Technology: A Case Report After 10 Years of Postloading Follow-Up.Case reports in dentistry · 2026
- Short Dental Implants as Strategic Support for Removable Partial Dentures in Mandibular Free-End Situations: A 3-Year Prospective Cohort Study.Clinical oral implants research · 2026
- Custom subperiosteal implant with immediate loading as a salvage solution after zygomatic implant failure: a case reportJournal of Oral Medicine and Oral Surgery · 2026