Journal of clinical medicine

Immediate Loading of 5.2-mm Ultra-Short Implants Supporting Maxillary Overdentures in the Severely Atrophic Maxilla: A Prospective Pilot Study.

Pieter-Jan Boderé, Wout Scharff, Cyrille France, Stefan Vandeweghe, Hugo De Bruyn, Renaat Coopman, Luc Van Doorne

Department of Reconstructive Dentistry, Faculty of Medicine and Health Sciences, Ghent University Hospital, Corneel Heymanslaan 10, 9000 Ghent, Belgium. · Department of Oral Health Sciences, Faculty of Medicine and Health Sciences, Ghent University Hospital, Corneel Heymanslaan 10, 9000 Ghent, Belgium.

Observational

Key points

From the paper's conclusion
  • Conclusions: This prospective pilot study demonstrates the feasibility of an immediately loaded treatment concept using 5.2-mm ultra-short implants splinted with a patient-specific CAD/CAM inter-implant bar (VD CLIC BAR®) to support maxillary overdentures in patients with severe maxillary atrophy.

Abstract

Background: Severe maxillary atrophy often precludes placement of conventional dental implants and frequently requires invasive bone augmentation procedures. This prospective pilot study evaluated a treatment concept using immediately loaded 5.2-mm ultra-short implants connected by a patient-specific CAD/CAM inter-implant bar system (VD CLIC BAR®) to support maxillary overdentures. Methods: Thirteen completely edentulous patients with severe maxillary atrophy (Cawood-Howell Class V or VI) were treated with six to eight immediately loaded 5.2-mm ultra-short implants connected by a patient-specific CAD/CAM inter-implant bar (VD CLIC BAR®) supporting a maxillary overdenture. The primary outcome was implant survival. Secondary outcomes included oral health-related quality of life (OHIP-14), self-reported chewing ability (VAS), implant stability (Periotest), and prosthetic rehabilitation. Results: A total of 96 initial implants and 8 additional implants were placed following early implant failures. The primary implant survival rate after two years was 83.3%. Implant failures occurred predominantly during early healing and were unevenly distributed across the cohort. Early failures were managed by placement of additional ultra-short implants, enabling definitive implant-supported rehabilitation in all patients. Periotest values demonstrated a significant increase in implant stability over time (p < 0.001). Median OHIP-14 scores improved from 32.0 (IQR 20.0-44.0) at baseline to 4.0 (IQR 1.0-20.0) at two years (p = 0.006). Median chewing ability at two years was 82.7 (IQR 50.1-91.9). Conclusions: This prospective pilot study demonstrates the feasibility of an immediately loaded treatment concept using 5.2-mm ultra-short implants splinted with a patient-specific CAD/CAM inter-implant bar (VD CLIC BAR®) to support maxillary overdentures in patients with severe maxillary atrophy. Although early implant failures occurred and required placement of additional ultra-short implants in some patients, all patients ultimately achieved functional implant-supported rehabilitation. These preliminary findings require confirmation in larger controlled studies with longer follow-up.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Immediate Loading of 5.2-mm Ultra-Short Implants Supporting Maxillary Overdentures in the Severely Atrophic Maxilla: A Prospective Pilot Study — Science Skim