A 4-mm-Short Implant Rehabilitation in the Posterior Maxilla With Dynamic Navigation Technology: A Case Report After 10 Years of Postloading Follow-Up.
Gerardo Pellegrino, Fabio Rossi, Andrea Oliverio, Subhi Tayeb, Claudia Angelino, Carlo Barausse, Pietro Felice
Unit of Oral Surgery, Department of Biomedical and Neuromotor Sciences (DIBINEM), University of Bologna, Bologna, Italy, unibo.it. · Private Practice, Bologna, Italy.
Key points
From the paper's conclusion- Within the limitations of a single case report, these findings suggest that the combination of dynamic navigation and ultrashort implants may represent a reliable and minimally invasive treatment option for single implant rehabilitation in severely atrophic posterior maxillary sites.
Abstract
Implant rehabilitation in the posterior maxilla with severe vertical bone atrophy remains clinically challenging, particularly when bone augmentation procedures are not feasible or are refused by the patient. The use of ultrashort implants combined with dynamic navigation has been proposed as a minimally invasive alternative in selected cases; however, long-term clinical evidence in the maxilla is still limited. This case report describes the 10-year clinical and radiographic outcomes of a single 4-mm ultrashort implant placed in the posterior maxilla using dynamic navigation technology. A 47-year-old nonsmoking female patient presented with a single edentulous maxillary first molar and severe vertical bone resorption (≤ 5 mm). The patient declined bone augmentation and fixed partial denture therapy. Implant placement was planned and performed under dynamic navigation guidance, followed by restoration with a single implant-supported crown. Clinical and radiographic follow-up was conducted regularly up to 10 years after prosthetic loading. Throughout the follow-up period, no biological or prosthetic complications were observed. Peri-implant soft tissues remained healthy, with no bleeding on probing or suppuration. Radiographic evaluation using standardized periapical radiographs revealed a mean marginal bone loss of 0.35 mm at 10 years. The implant-supported crown maintained stable function and structural integrity, and the patient reported high satisfaction with the treatment outcome. Within the limitations of a single case report, these findings suggest that the combination of dynamic navigation and ultrashort implants may represent a reliable and minimally invasive treatment option for single implant rehabilitation in severely atrophic posterior maxillary sites. Further prospective studies with larger sample sizes and long-term follow-up are required to confirm the predictability and reproducibility of this approach.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Immediate Loading of 5.2-mm Ultra-Short Implants Supporting Maxillary Overdentures in the Severely Atrophic Maxilla: A Prospective Pilot Study.Journal of clinical medicine · 2026
- Comprehensive Oral Rehabilitation With Corticobasal Implants: Restoring Function and Aesthetics.Cureus · 2026
- The Digital Renaissance of Customized Subperiosteal Implants-Clinical Outcomes, Surgical Workflow, and Current Evidence for the Rehabilitation of Severely Atrophic Jaws: A Narrative Review.Dentistry journal · 2026
- Hybrid implant-supported rehabilitation of severely atrophic jaws using custom-made subperiosteal and conventional endosseous implants: A retrospective case seriesJournal of Cranio-Maxillofacial Surgery · 2026
- Complications and management of modified custom-made subperiosteal implants in severely atrophic maxilla and mandible: a retrospective cohort of 211 implants.International journal of oral and maxillofacial surgery · 2026
- The Application of Autonomous Dental Implant Robots in Avoiding Maxillary Sinus and Making Full Use of Sinus Septa for Fixed Restoration Supported by Implants: A Case Report.Case reports in dentistry · 2026