Custom subperiosteal implant with immediate loading as a salvage solution after zygomatic implant failure: a case report
Jean Martinien Engoue N’Zeele, Mickaël Samama
Key points
From the paper's conclusion- Conclusion: This case supports custom digitally designed and manufactured subperiosteal implants as a salvage strategy after failure of both conventional and zygomatic implants in severely atrophic maxillae, provided that case selection, digital planning and interdisciplinary collaboration are rigorous.
Abstract
Introduction: Recurrent implant failure in severely atrophic maxillae remains a major therapeutic challenge, particularly after bone grafting and conventional implant placement. Zygomatic implants offer high survival rates but remain exposed to specific technical, biological and anatomical complications, and their failure is difficult to manage. Observation: We report a 61-year-old woman with Cawood and Howell class VI maxillary atrophy and repeated mechanical and biological complications, including graft failure and fatigue fracture of zygomatic implants. A custom-made subperiosteal framework was digitally planned using a dual cone-beam computed tomography and prosthetic protocol to engage residual zygomatic and paranasal cortices. Under general anaesthesia, a full-thickness flap exposed the maxilla, a buccosinusal communication was treated, and the framework was passively fixed with multiple screws before tension-free closure and immediate connection of a screw-retained full-arch prosthesis. Immediate functional loading was achieved without early mechanical complications, with satisfactory soft-tissue healing, sinus closure, prosthetic stability and high patient-reported functional and aesthetic satisfaction at 4-month follow-up. Conclusion: This case supports custom digitally designed and manufactured subperiosteal implants as a salvage strategy after failure of both conventional and zygomatic implants in severely atrophic maxillae, provided that case selection, digital planning and interdisciplinary collaboration are rigorous.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Complications and management of modified custom-made subperiosteal implants in severely atrophic maxilla and mandible: a retrospective cohort of 211 implants.International journal of oral and maxillofacial surgery · 2026
- Hybrid implant-supported rehabilitation of severely atrophic jaws using custom-made subperiosteal and conventional endosseous implants: A retrospective case seriesJournal of Cranio-Maxillofacial Surgery · 2026
- Surgical Management of Severe Maxillary Atrophy Using Customized Subperiosteal Titanium Implants: Report of Two Clinical Cases With 42 Months of Follow-Up.Case reports in dentistry · 2026
- Two-Stage Management of Severe Maxillary Atrophy With Maxillary Advancement, Bone Reconstruction, and Custom Subperiosteal ImplantJournal of Craniofacial Surgery · 2026
- The Digital Renaissance of Customized Subperiosteal Implants-Clinical Outcomes, Surgical Workflow, and Current Evidence for the Rehabilitation of Severely Atrophic Jaws: A Narrative Review.Dentistry journal · 2026
- CONSERVATIVE MANAGEMENT OF A CERVICALLY FRACTURED ZYGOMATIC IMPLANT USING A NOVEL TITANIUM DEVICE: A TECHNICAL REPORT WITH BIOMECHANICAL VALIDATION AND 24-MONTH FOLLOW-UP.Journal of stomatology, oral and maxillofacial surgery · 2026