Beyond the Monomer: Camphorquinone, TPO, and BAPO as Leachates of Light-Cured and 3D-Printed Dental Polymers-Radical Chemistry, Redox Signalling, and the Dose-Realism Gap.
Marcin Mikulewicz, Edward Kijak
Department of Dentofacial Orthopaedics and Orthodontics, Division of Facial Abnormalities, Wroclaw Medical University, Krakowska 26, 50-425 Wroclaw, Poland. · Department of Prosthodontics, Wroclaw Medical University, Krakowska 26, 50-425 Wroclaw, Poland.
Key points
From the paper's conclusion- We critically appraise the photochemistry, elution behaviour, molecular stress responses, and exposure data for CQ, TPO, and BAPO, weighted toward orthodontic appliances, and ask whether a margin of safety can be estimated.
Abstract
Research on the biological cost of resin-based dental materials has focused almost exclusively on residual methacrylate monomers. The photoinitiators-camphorquinone (CQ) with its amine co-initiator, and the acylphosphine oxides TPO and BAPO-remain partly unconsumed, can elute, and are seldom measured. Vat photopolymerisation, where acylphosphine oxides dominate, makes this omission material. We critically appraise the photochemistry, elution behaviour, molecular stress responses, and exposure data for CQ, TPO, and BAPO, weighted toward orthodontic appliances, and ask whether a margin of safety can be estimated. Within studies, TPO is 15- to 250-fold more cytotoxic than CQ, and neither TPO nor BAPO raised intracellular reactive oxygen species measurably in the two studies that measured it, so the CQ redox narrative cannot be assumed to transfer. Extractable TPO content of printed splint and orthodontic resins spans about a thousand-fold; the highest values exceed the TPO EC50 numerically, but exhaustive extraction is not an intraoral dose. No retrieved study has measured any photoinitiator in human saliva. Photoinitiator hazard is established in vitro; a clinically relevant, physiologically anchored margin of safety cannot currently be estimated reliably. TPO's EU cosmetics prohibition alongside its continued intraoral use sharpens this asymmetry.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Photoinitiator Systems in Dental Resin-Based Composites: Mechanisms, Performance, and Clinical ImplicationsF1000Research · 2026
- Spectral Compatibility Between Photoinitiators and LED Curing Lights: Photographic and Spectroscopic Evidence from Model Resin Systems.Materials (Basel, Switzerland) · 2026
- In Vitro Cytotoxicity of Three Dimethacrylate-Based Photopolymer Resins for 3D-Printed Dental Restorations: A Qualitative Morphological Screening on Human Fibroblasts.Journal of functional biomaterials · 2026
- Comparison of three dental resins for 3D printing of orthodontic appliances: Comparison of leaching, biocompatibility, and thermo-mechanical properties after post-curing and agingDental Materials · 2025
- Medium-Specific Elemental and Ionic Screening of Archived Denture-Base Immersion Extracts: Matrix Effects, Blank Provenance, and Reporting RequirementsProsthesis · 2026
- Per-Layer UV Exposure-Dependent Cytotoxicity of 3D-Printed Aligner Resins and Estrogen-like Activity Screening.Polymers · 2026