Simulation-Based Implementation of Germicidal UV-C Light Within a GMP Setting
Mahmoud Tawfieq, Nicolaj Stelzner Grønvall, Britt Rasmussen, Line Thaulov Østergaard
Key points
From the paper's conclusion- The mean Colony-Forming Unit (CFU) count decreased from 3.60 before UV-C implementation to 1.94 after implementation, corresponding to a 46% reduction.
Abstract
Germicidal UV-C light has been around for 120 years, and while it is widely utilized in the food industry, it is less implemented within the pharmaceutical industry. In this paper, we present an optical-assisted implementation process of UV-C lamps within a Good Manufacturing Practice (GMP) setting. The presented approach consists of six steps: understanding the room; optical simulations; dose, cycle and frequency; safety; maintenance plan; and installation, verification and results. Each of these steps is described by following an actual implementation example inside a class D/C Personal Airlock (PAL). The Environmental Monitoring (EM) effect is compared 12 months prior to and 12 months after the implementation of the UV-C lamps. Here, it is shown that the total number of alerts was reduced from 32 (6.0%) to 12 (2.6%), the three-in-a-row alerts were reduced from 3 to 0, while the action levels were reduced from 4 (0.8%) to 0 (0.0%). The mean Colony-Forming Unit (CFU) count decreased from 3.60 before UV-C implementation to 1.94 after implementation, corresponding to a 46% reduction. Finally, we discuss different approaches of implementation into other types of cleanrooms, and possible mitigation actions should a UV-C system underperform.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Germicidal Ultraviolet C (UV-C) Light for Surface Disinfection in Hospitals: Mapping the Evidence on Devices, Parameters, Effectiveness, and ImplementationHygiene · 2026
- UV-C disinfection of endocavitary ultrasound probes against Candidozyma auris : a rapid and chemical-free solutionAntimicrobial Stewardship & Healthcare Epidemiology · 2026
- Ultraviolet-C Light Emitter as a Method for Reducing Bacterial Contamination of Ophthalmic Instruments.Journal of ophthalmology · 2026
- Radiometrically Equivalent Comparison of 254 nm Low-Pressure Mercury Lamps and InGaN 280 nm UV-C LEDs for Surface Disinfection.ACS omega · 2026
- Environmental Impact of a Novel UV-C Disinfection Machine for Non-Channel Flexible Laryngoscopes.Laryngoscope investigative otolaryngology · 2026
- Defining Operational UV-C Dose Requirements for Autonomous Disinfection of Clinically Relevant Pathogens Across Healthcare and High-Touch SurfacesbioRxiv · 2026