VENTILA2: A Fuzzy Logic-Based Simulation and Decision-Support Framework for Pressure-Controlled Ventilation-A Proof of Concept.
Lucas Carrera-Villar, Julia López-Canay, Jaime Álvarez-Vázquez, Manuel Casal-Guisande, María Torres-Durán, Alberto Fernández-Villar
NeumoVigo I+i Research Group, Galicia Sur Health Research Institute (IIS Galicia Sur), SERGAS-UVIGO, 36312 Vigo, Spain.
Key points
From the paper's conclusion- This study aims to propose and define a simulation platform and decision support prototype, named VENTILA2, to optimize pressure-controlled ventilation strategies.
Abstract
Background and Objectives: Non-invasive mechanical ventilation is the first-line treatment for managing acute respiratory failure. However, patient variability and complex pulmonary mechanics complicate therapy adjustments, frequently leading to ventilator-induced lung injuries. This study aims to propose and define a simulation platform and decision support prototype, named VENTILA2, to optimize pressure-controlled ventilation strategies. Methods: The system integrates a bicompartmental series model of the respiratory system incorporating severity-stratified physiological profiles of chronic obstructive pulmonary disease and acute respiratory distress syndrome, and it is coupled with a Mamdani fuzzy inference system. This architecture maps inspiratory time adjustments based on pressure errors and their derivatives across predefined clinical profiles within a scenario-based feedforward parameter-mapping framework. Results: Evaluated through quantitative operational verification across all profiles and proof-of-concept case studies, the platform successfully recreates complex clinical scenarios, accurately simulating phenomena such as accelerated lung emptying in severe acute respiratory distress syndrome and air trapping in moderate chronic obstructive pulmonary disease. Conclusions: VENTILA2 provides a controlled simulation environment for evaluating pathology-specific ventilatory configurations across simulated profiles prior to clinical implementation, though it remains an early-stage prototype whose clinical effectiveness, safety, and robustness remain to be rigorously evaluated.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- VentiProtect ARDS, vibe coding lung protection: a five-minute clinician-built ventilator tool as proof-of-concept for physician prompt engineering.Anaesthesia, critical care & pain medicine · 2026
- Design assessment and preliminary performance evaluation of a novel device for non-invasive emergency treatment of acute respiratory failure.Biomedical engineering letters · 2026
- Operating-envelope assessment of static-pressure reset control in VAV systemsE3S Web of Conferences · 2026
- Effect of Automated Closed-Loop Ventilation vs Protocolized Conventional Ventilation on Ventilator-Free Days in Critically Ill AdultsJAMA · 2025
- Intelligent Lung Support in the Intensive Care Unit (IntelliLung): study protocol for an international observational, prospective, multicentre study.BMJ open · 2026