Input Current Harmonic Suppression in a 12-Pulse Delta/Wye-Connected System Using a Novel Passive Auxiliary Circuit
Bowen Gu, Shuang Rong, Huaiyu Guo, Fangang Meng, Wanlin Guan, Mingjiang Zhang, Zhipeng Liu, Chen Yang,
Key points
From the paper's conclusion- The measured input current THD is 3.62% at the reported operating point.
Abstract
The growing demand for high-power rectification has imposed increasingly strict power quality requirements on modern electrical grids. As prevalent nonlinear front-end devices, multi-pulse rectifiers (MPRs) inject substantial harmonic currents into the AC mains. Targeting the inherent shortcomings of conventional MPRs, this study develops a passive solution—termed the passive auxiliary circuit (PAC)—for harmonic mitigation at the source. The proposed system integrates a 12-pulse main rectifier, based on a delta/wye-connected transformer (DWCT), with the PAC. The PAC contains two interphase reactors (IPRs) and 10 diodes. A detailed operational analysis, grounded in Kirchhoff’s Current Law (KCL), is conducted to determine the circuit’s injection current characteristics across its distinct conduction modes. Furthermore, the IPR turns ratios are evaluated using an analytical input current THD model. The calculated combined apparent power rating of the IPRs is 2.53% of the DC output power, while the auxiliary diode conduction loss is estimated as 1.34ILUon under the constant forward-voltage drop assumption (IL: load current; Uon: diode voltage drop). Simulation and prototype testing support the PAC’s harmonic suppression capability. The measured input current THD is 3.62% at the reported operating point.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Low-Harmonic Front-End Rectifier for EV Chargers with Dual Single-Phase Auxiliary Rectifier Pulse-Tripling CircuitVehicles · 2026
- A Dual Sharing Strategy in Multi-Task Learning for Harmonic Signal DecompositionSymmetry · 2026
- Optimized Switching-Frequency Control for Improved Efficiency in Three-Phase Isolated Y-RectifiersEnergies · 2026
- Design and Experimental Verification of 300 W DAB Converter for Educational ApplicationsApplied Sciences · 2026
- Ripple-Current Suppression in Two-Phase Interleaved Bidirectional Buck/Boost Converters Using Auxiliary ConverterElectronics · 2026
- Modeling and Experimental Validation of Transformer‐Reflected Reactance Cancelation and Effective Inductance Reduction for 50‐Hz Pulsed‐DC Resonant Voltage MultiplicationInternational Journal of Circuit Theory and Applications · 2026