Modeling and Experimental Validation of Transformer‐Reflected Reactance Cancelation and Effective Inductance Reduction for 50‐Hz Pulsed‐DC Resonant Voltage Multiplication
Donghui Chen
Key points
From the paper's conclusion- The findings validate a passive switched near‐resonant voltage multiplication mechanism driven by transformer‐coupled DC/AC decoupling and fixed‐frequency inductive reactance cancelation at 50 Hz, suitable for controller‐free auxiliary biasing applications.
Abstract
Low‐frequency voltage multiplication in passive switched networks without capacitor stacking or active switches requires simultaneous DC path continuity and AC inductive‐reactance compensation, which cannot be achieved by a simple series lumped capacitor. While broadband negative reactance typically relies on active negative‐impedance converters, distributed transmission lines, or digitally controlled converters, this study develops a Foster‐compliant equivalent‐impedance and first‐harmonic approximation (FHA) framework for interpreting 50‐Hz pulsed‐DC voltage multiplication via transformer‐reflected capacitive reactance cancelation. A path‐constrained dual‐inductor, five‐diode, transformer‐capacitor coupled topology was analyzed using a parasitic‐calibrated equivalent‐impedance model. The model characterizes how a secondary‐side capacitive load reflected through a 1:1 transformer decouples DC conduction from AC reactance compensation, producing a single‐frequency effective series inductance reduction () at the 50‐Hz fundamental frequency. Analytical predictions were evaluated through LTspice transient simulations, bench‐scale measurements, parametric sweeps, and three structural ablation controls. The analytical model predicted a reflected capacitive reactance of approximately at 50 Hz, while the measured value was (corresponding to an effective inductance reduction of at 50 Hz), partially compensating the main‐path series inductive reactance of . At /50 Hz input, the measured DC output reached with a unfiltered peak‐to‐peak ripple across a load, yielding an RMS‐referenced voltage gain of and exceeding the input peak voltage by approximately . The baseline simulated output agreed with measurement within , and parametric sweeps showed strong simulation‐experiment correlation (). Three ablation controls exhibited output degradation after structural modification, and uncertainty‐propagated power‐balance analysis confirmed passive energy conservation ( with an closure residual). The findings validate a passive switched near‐resonant voltage multiplication mechanism driven by transformer‐coupled DC/AC decoupling and fixed‐frequency inductive reactance cancelation at 50 Hz, suitable for controller‐free auxiliary biasing applications.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Adaptive Dual Active Bridge Converter With LCL Filter Using Switch‐Controlled Capacitor for Inductance Variation CompensationInternational Journal of Circuit Theory and Applications · 2026
- DC-Link Voltage Regulation in a Single-Isolation-Stage Multioutput Solid-State Transformer for Wide-Range DC OutputsarXiv · 2026
- A Symmetrical Five-Switch Hybrid Boost Converter With Output Voltage Ripple Reduction and Right-Half-Plane Zero EliminationIEEE Transactions on Power Electronics · 2025
- Input Current Harmonic Suppression in a 12-Pulse Delta/Wye-Connected System Using a Novel Passive Auxiliary CircuitEnergies · 2026
- Output Capacitorless Low-Dropout Regulator Circuit Design with High Power Supply Rejection RatioElectronics · 2026
- Three-Phase-Input Inductive Wireless Power Transfer System for Rectifier-Output Voltage Ripple ReductionElectronics · 2026