Optimized Switching-Frequency Control for Improved Efficiency in Three-Phase Isolated Y-Rectifiers

Khaled A. A. Mohammed, Ahmed Y. Farag, Paolo Mattavelli

Key points

From the paper's conclusion
  • At 400V and 300W, the measured loss falls by 38.6, raising the efficiency from 85.1 to 90.3 .

Abstract

The single-stage three-phase isolated Y-rectifier (iYR) merges power-factor correction and galvanic isolation into two conventional B6 bridges. Its power is conventionally regulated by the phase-shift angle alone at a fixed switching frequency. At light load, the transformer current then forms high-peak pulses whose rms value is large relative to the transferred power, and the efficiency falls. This paper proposes a hybrid phase-shift and variable-frequency control that raises the switching frequency as the load falls, without altering the internal space-vector timings. At the lightest tested load, about 300W, the measured rms current falls by roughly 50 when the frequency is raised from 25kHz to 80kHz. The loss-optimal frequency is identified from hardware measurements rather than from simulation, and is stored as a two-dimensional look-up table indexed on the power reference and the dc output voltage. The strategy is validated on a 3kW prototype over a 350V–450V dc-bus range and a 25kHz–80kHz frequency range. At 400V and 300W, the measured loss falls by 38.6, raising the efficiency from 85.1 to 90.3 . Two transformer designs differing only in the magnetizing inductance are compared, which sets the frequency range over which the strategy reduces the loss.