Key points
From the paper's conclusion- In battery-fed small wind-energy systems, the single-phase stand-alone inverter draws its double-line-frequency power pulsation from the battery, so the RMS battery current, not its mean, sets the battery-side ratings and losses.
Abstract
In battery-fed small wind-energy systems, the single-phase stand-alone inverter draws its double-line-frequency power pulsation from the battery, so the RMS battery current, not its mean, sets the battery-side ratings and losses. This paper derives a closed-form approximation for this current from the output-power variance, exact under three stated assumptions (stiff battery voltage, no internal buffering, affine losses), and an upper bound that, for sinusoidal output voltage, needs only aggregate readings. The approximation is assessed against reference measurements of a 275 VA inverter at three light-load points (4–25 W). The RMS-to-mean ratio is compatible at all three, whereas the conventional sinusoidal estimate underestimates it for electronic lamps by 24–25%. Two points, however, identify the loss parameters, so the absolute current agrees there by construction. At the only independent point, a compact fluorescent lamp, the measured 1.20 A exceeds both the prediction and the waveform-independent bound (1.03 and 1.04 A). The assumptions and the readings therefore cannot jointly describe this point, and the bound identifies this inconsistency without any assumption on the load waveform. Theoretical design estimates, conditional on the stated assumptions, illustrate the use of the approximation for controller ratings, DC-link decoupling and the idle-loss share of turbine yield at six Saudi cities.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Unified Power Calculation Scheme for Single-Phase Droop-Based Inverters Considering the Use of Nonlinear LoadsEnergies · 2026
- Control System Design and Implementation of Battery-Assisted Quasi-Impedance-Source Inverter for Standalone Power Generation.Sensors (Basel, Switzerland) · 2026
- Performance Boundaries of Hybrid Photovoltaic–Battery Inverters Under Dynamic, Unbalanced, and Grid Disturbance ConditionsEnergies · 2026
- Equivalent Input Disturbance Estimation Combined with Observer Kalman Filter Identification for Three-Phase Four-Leg Inverters in an AC Battery ApplicationEngineering Research Express · 2026
- Boundary-Current-Mode Control for Single-Phase Microinverters: ZVS Operation, Modulation Strategies, and Reset-Current TradeoffsElectronics · 2026
- Power quality impact of residential LED loads under grid and isolated generator supplyElectrical Engineering · 2026