A Unified Power Calculation Scheme for Single-Phase Droop-Based Inverters Considering the Use of Nonlinear Loads
Carlos Gustavo Castelo Branco, Jose Matas, Zhihao Min, Ganzhou Yao, Josep Maria Guerrero
Key points
From the paper's conclusion- The dynamic performance of droop-controlled single-phase voltage-source inverters (VSIs) strongly depends on the accurate and fast calculation of active (P) and reactive (Q) powers under nonlinear load (NLL) conditions.
Abstract
The dynamic performance of droop-controlled single-phase voltage-source inverters (VSIs) strongly depends on the accurate and fast calculation of active (P) and reactive (Q) powers under nonlinear load (NLL) conditions. Existing PQ calculation methods have been developed independently, most using a second-order generalized integrator (SOGI) approach, masking their structural relationships. This paper introduces a unified framework that interprets these PQ calculation approaches as combinations of input filters, intermediate notch filters, and output low-pass filters, enabling a clear spectral-domain analysis. Using this framework, the paper reveals that the current-side orthogonal filter in the fastest previously reported method (PQ4) causes a reactive power undershoot during load transients due to insufficient filtering. To overcome this limitation, a novel scheme (PQ2m) relocates the orthogonal filter to the voltage side and adds current-side SOGI filtering for improved distortion rejection. Analytical dynamic modeling enables a systematic design procedure, achieving an overshoot-free, dominant second-order response. Furthermore, incorporating notch filters (NFs) yields the PQ2mn variant and alternative PQ2mnb and PQ2mnc designs, which significantly suppress the output ripple while further accelerating the response speed. Hardware-in-the-Loop (HIL) results confirm settling-time reductions of up to 92.9% (PQ2m/PQ2mn), 95.75% (PQ2mnb), and 96.9% (PQ2mnc) compared to the conventional PQ1 method. Among all configurations, PQ2mn provides the best overall trade-off between dynamic enhancement and computational complexity.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Reactive power sharing between parallel VSI into islanded microgrid based on PSO algorithmScientific Reports · 2026
- A Hybrid LQR–PI Control Strategy with Virtual Impedance for Next-Generation Inverter-Based Microgrids: Enhanced Dynamic Stability and Power QualityEnergies · 2026
- Energy storage-enabled fractional-order virtual synchronous generator for DC-link voltage regulation in DC microgrid under load and renewable disturbancesScientific Reports · 2026
- A Practical Controller-Aware LDC Parameter Design Method for SVRs Considering Bidirectional Power FlowEnergies · 2026
- Current-Controlled Voltage Source Converters for Power Quality Improvement in Hybrid Microgrids: Performance and LimitationsEPJ Web of Conferences · 2026
- Enhanced jellyfish search-optimized cascaded fuzzy-FOPI control of a three-phase dynamic voltage restorer for power quality improvementScientific Reports · 2026