Parameter-Adaptive VMD and Secondary Wavelet Filtering for Cable Partial Discharge Denoising
Ke Shang, Jianwei Song, Yikang He, Lele Liu, Jiahao Geng
Key points
From the paper's conclusion- These results support online insulation monitoring of high-voltage cables.
Abstract
Among the various online monitoring methods for assessing the insulation condition of high-voltage cables, partial discharge (PD) detection is among the most widely applied. However, PD signals acquired in field environments are highly susceptible to noise interference. To address this issue, this paper proposes a novel denoising approach integrating parameter-adaptive Variational Mode Decomposition (VMD) and secondary wavelet filtering. First, the Rime Optimization Algorithm (RIME) is employed to adaptively search for the optimal decomposition parameters of VMD, specifically the mode number K and penalty factor α. The parameter-adaptive VMD then decomposes the noisy PD signal into a series of intrinsic mode functions (IMFs). Next, Composite Multiscale Fuzzy Dispersion Entropy (CMFDE) is introduced to quantify the complexity of each IMF, enabling the accurate distinction between effective signal components and noise-dominated modes. Finally, an Improved Wavelet Threshold (IWT) technique is applied to the selected effective components as a secondary filtering process, effectively suppressing residual noise while preserving waveform features. Simulation experiments evaluate the signal-to-noise ratio and reconstruction accuracy, while controlled cable measurements illustrate improved PD pulse visibility. At an input signal-to-noise ratio of −4 dB, the output signal-to-noise ratio reaches 12.40 dB with a normalized correlation coefficient of 0.972. These results support online insulation monitoring of high-voltage cables.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Research on Noise Reduction of Switchgear Partial Discharge Signals Based on CEEMDAN and Improved Wavelet ThresholdingIEEJ Transactions on Electrical and Electronic Engineering · 2026
- Dynamic Hyperbolic Tangent PSO-Optimized VMD for Pressure Signal Denoising and Prediction in Water Supply NetworksEntropy · 2025
- Partial Discharge Detection and Localization in Power Transformers Using an Integrated Fiber‐Optic Acoustic Monitoring FrameworkJournal of Sensors · 2026
- Optical fiber sensing and partial discharge fault diagnosis for power cable health monitoringMeasurement Science and Technology · 2025
- Research on partial discharge signal recognition and classification of power transformer based on acoustic-VMD and CNN-LSTMPLoS ONE · 2025
- Spatial propagation structure guided grouped weighted prediction error dereverberation algorithm for partial discharge acoustic localizationEngineering Research Express · 2026