Soil Resistivity Measurement Methods and Data Inversion for Grounding System Design
Massimo Mitolo, Erika Stracqualursi, Rodolfo Araneo
Key points
From the paper's conclusion- Soil electrical resistivity is a primary input parameter for grounding system design, and its spatial variation should be represented using an appropriate multilayer soil model.
Abstract
The design of grounding systems must ensure the electrical safety of installations and account for site-specific conditions. Soil electrical resistivity is a primary input parameter for grounding system design, and its spatial variation should be represented using an appropriate multilayer soil model. This paper reviews the principal techniques and electrode configurations used to measure soil electrical resistivity and discusses the advantages and limitations of each method. It also presents the most used conventions for consistently defining the depth of investigation associated with electrode arrays used in vertical electrical soundings. Beyond electrode geometry, the paper addresses the principal remaining sources of uncertainty in a resistivity-derived soil model: electrode polarization and instrument frequency selection, the temperature and moisture dependence of the measured resistivity, the repeatability of individual readings, and, where an independent geophysical or geotechnical measurement is available, cross-validation of the inverted model’s interfaces against it. Data inversion, the mathematical procedure used to estimate the true soil resistivity distribution from measured apparent resistivity values, is also presented. This paper is intended as a reference for practicing engineers who conduct soil resistivity surveys and require reliable data for grounding system design.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Electrical Resistivity as a Supplementary Site Characterisation Tool Within an Integrated Geotechnical Investigation Framework for Calcareous Desert DepositsApplied Sciences · 2026
- Transient Temperature Rise and Grounding Characteristics of Vertical DC Grounding Electrodes Considering Soil Electro-Thermal CouplingEnergies · 2026
- Derivation of Equivalent Soil Thermal Resistivity for EHVDC Cable Design in Layered Offshore Seabed ConditionsEnergies · 2026
- A Field Comparison of Four Apparent Resistivity Definitions in Controlled Source Electromagnetic SurveysApplied Sciences · 2026
- Analysis of the Implementation of Effective Grounding in 400 kV Overhead LinesEnergies · 2026
- Impulse Effective Length of Horizontal Grounding Electrodes for 220 kV Transmission Towers Under Different Soil ConditionsEnergies · 2026