Gain-Scheduled Internal Model Control of Full-Bridge CLLC Resonant Converters for Wide-Range CC/CV Regulation: A Simulation-Based Study
Shyr-Long Jeng, Wei-Hua Chieng
Key points
From the paper's conclusion- Simulation results on a 750-V/11-kW converter show that, for CV regulation from 330 V to 900 V and CC regulation from 5 A to 14 A over a load range of 25–150 Ω, the proposed GS-IMC achieves a settling time of 12 ms, eliminates the tracking plateaus, and reduces the overshoot compared with a fixed-gain IMC.
Abstract
This paper proposes a gain-scheduled internal model control (GS-IMC) strategy for wide-range constant-voltage (CV) and constant-current (CC) regulation of a full-bridge CLLC resonant converter. The symmetric CLLC resonant network inherently enables zero-voltage switching (ZVS) of the primary-side switches; the contribution of this work lies in the control-oriented modeling and regulation of the converter under pulse-frequency modulation (PFM). Traditional first-harmonic approximation (FHA) models neglect the dominant pole formed by the output capacitance and load resistance and lose accuracy far from resonance, which limits their usefulness for closed-loop design. To overcome these limitations, the nonlinear voltage-gain and frequency-sensitivity characteristics of the converter are characterized over the full range of switching frequency and load using Piecewise Linear Electrical Circuit Simulation (PLECS). The resulting small-signal sensitivities are stored in two-dimensional (2D) lookup tables, from which the parameters of the internal plant model are scheduled according to the measured operating point, without online parameter estimation. The IMC controller is then derived from the scheduled model, so a single filter time constant sets the closed-loop response at all operating points. Simulation results on a 750-V/11-kW converter show that, for CV regulation from 330 V to 900 V and CC regulation from 5 A to 14 A over a load range of 25–150 Ω, the proposed GS-IMC achieves a settling time of 12 ms, eliminates the tracking plateaus, and reduces the overshoot compared with a fixed-gain IMC.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Dual-Variable Maximum-Efficiency Tracking Control for a High-Step-Up Boost-Integrated Dual-LLC Resonant ConverterElectronics · 2026
- Design and Implementation of a High-Gain Bidirectional CLLC Resonant Converter for Photovoltaic Energy Storage SystemsElectronics · 2026
- A Comparative Assessment of Power Converter Control Strategies: From Linear Control to Machine Learning ApproachesIEEE Industrial Electronics Magazine · 2026
- Feasibility Region Analysis of a Single-Phase PWM Current Source Converter for Constant Power Loads in Smart Grid and Microgrid ApplicationsTechnologies · 2026
- Adaptive Inductor and Frequency Management for Integrated Power ConvertersarXiv · 2026
- Nonlinear Control and Current-Sensorless Online Load Estimation of a Buck ConverterMathematics · 2026