Adaptive Inductor and Frequency Management for Integrated Power Converters
Rami Rasheedi, Salma Abdelzaher, Inna Partin-Vaisband
Key points
From the paper's conclusion- Simulation results demonstrate a 4.5 percentage-point improvement in average efficiency and up to a 32% reduction in average power loss relative to fixed configurations, highlighting the effectiveness of adaptive inductance-frequency management in integrated power delivery systems with dynamic load profiles.
Abstract
This work presents a digitally controlled adaptive power conversion framework that dynamically co-optimizes inductor configuration and switching frequency to achieve high efficiency across a wide range of load conditions. Conventional buck converters are typically optimized for a single operating point, leading to efficiency degradation under dynamic loads due to mismatches between inductance, switching frequency, and load current. To address this limitation, a reconfigurable inductor architecture is proposed. With this approach, the effective inductance and switching frequency are adjusted at runtime with on-chip digital controller. An end-to-end design methodology is developed, integrating physics-based analytical modeling, finite element method (FEM) simulations, and an optimization framework to determine preferred operating points across the load range. The resulting configurations are stored in a lookup table and implemented in real time through a low-overhead control scheme. The system explicitly accounts for both inductor and switching device losses, enabling co-optimization of conduction and switching losses within current ripple and continuous conduction mode (CCM) constraints. To ensure robust operation under fast load transients, a hysteresis-based control strategy is introduced to mitigate temporary CCM violations caused by sensing latency. An entry-margin condition is derived under which continuous conduction is guaranteed for a bounded load slew rate. Simulation results demonstrate a 4.5 percentage-point improvement in average efficiency and up to a 32% reduction in average power loss relative to fixed configurations, highlighting the effectiveness of adaptive inductance-frequency management in integrated power delivery systems with dynamic load profiles.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Adaptive Dual Active Bridge Converter With LCL Filter Using Switch‐Controlled Capacitor for Inductance Variation CompensationInternational Journal of Circuit Theory and Applications · 2026
- Digital Modeling and Optimal Design Tool for DAB Converter: A Case Study on Efficiency Improvement by Control Strategies and Power SemiconductorsIEEE Transactions on Power Electronics · 2026
- Continuous-Discrete Dual-Domain Co-Design for Optimized Digital Control of Power ConvertersarXiv · 2026
- Asymmetrical duty cycle controlled dual-unit multi-load induction heating system with fixed-frequency ZVS operationDiscover Applied Sciences · 2026
- An Inductively Assisted N :1 Switched-Capacitor Ladder ConverterarXiv · 2026
- Efficiency Optimization of LLC Resonant Converters via Combined Analytical Modeling and Data-Assisted VisualizationElectronics · 2026