Nonlinear Control and Current-Sensorless Online Load Estimation of a Buck Converter
Fatih Evran
Key points
From the paper's conclusion- These experimental results demonstrate the feasibility of real-time current-sensorless nonlinear control with online load-resistance estimation on an embedded buck-converter platform.
Abstract
This paper presents a current-sensorless control architecture for a buck DC–DC converter that integrates input–output feedback linearization (IOFL) with an extended Kalman filter (EKF). IOFL is applied to the averaged converter model to obtain a linear input–output relation, allowing the proportional–integral–derivative (PID) gains to be selected directly from a prescribed damping ratio and natural frequency. To eliminate direct inductor-current feedback, an augmented EKF jointly estimates the inductor current and load resistance using the measured input and output voltages together with the applied duty ratio. A common lossy averaged model is employed in both the IOFL cancellation law and the EKF prediction step, thereby maintaining model consistency between the controller and estimator. The proposed architecture is experimentally evaluated under start-up conditions and abrupt changes in load resistance, input voltage, and reference voltage. Compared with a fixed-gain proportional–integral (PI) controller, the proposed method reduces the inductor-current overshoot at start-up from 62.5% to 12.5% and the start-up time from 16.7ms to 1.6ms. For a 48V-to-70V input-voltage step, the output-voltage overshoot is reduced from 6.7V to 0.2V. The EKF yields maximum absolute relative estimation errors of 1.8% for both the inductor current and load resistance. These experimental results demonstrate the feasibility of real-time current-sensorless nonlinear control with online load-resistance estimation on an embedded buck-converter platform.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Learning Higher Order DC-DC Converter Control from InversionarXiv · 2026
- A Bias-Augmented ARX/RLS Adaptive RST Controller for Nonideal DC–DC Buck Converters Under Line and Load DisturbancesSymmetry · 2026
- Adaptive Average Current-Mode Control of a Buck Converter Supplying Plasma Arc LoadsarXiv · 2026
- Flatness-based Neural Network Control of DC-DC ConvertersarXiv · 2026
- Output Voltage Control of a Half-Bridge LLC Resonant Converter Based on Nonsingular Fast Terminal Sliding Mode Active Disturbance Rejection ControlEngineering Research Express · 2026
- Impact of Model Accuracy on Control Performance in DC–DC Boost Converters: An Experimental StudyEnergies · 2026