A Triple Compensation Method for Correcting Temperature-Induced Distance Errors in SPAD-Based d-ToF LiDAR
Dokon Kim
Key points
From the paper's conclusion- Experimental validation across a temperature range of −20 °C to 60 °C demonstrates that the proposed triple compensation reduces the peak-to-peak distance error from 1.11 m to 0.16 m (an 85.6% reduction) and decreases the standard deviation from 0.30 m to 0.035 m (an 88.3% reduction), achieving an 8.57-fold improvement in precision.
Abstract
This paper proposes a Triple Compensation Method to systematically eliminate thermal degradation and distance measurement errors induced by temperature variations in SPAD (Single-Photon Avalanche Diode)-based direct Time-of-Flight (d-ToF) LiDAR sensors. As temperature rises, the combined effects of reduced emission efficiency in the transmitter’s Laser Diode (LD) and an increase in the breakdown voltage (VBD) of the receiver’s SPAD element result in decreased peak intensity and pulse width distortion. These factors directly cause rising-edge timing distortions, introducing significant walk errors and thermal distance drift. The proposed triple compensation scheme comprises three distinct stages: 1. Track 1 (Dynamic Gain Control): Real-time monitoring of junction temperature dynamically adjusts the bias voltage (VBias) to maintain constant excess voltage (VEx), mitigating degradations in Photon Detection Efficiency (PDE) and gain. 2. Track 2 (Walk Error Compensation): Residual non-linear walk errors are corrected by real-time tracking of peak intensity using an empirically derived look-up table (LUT). 3. Track 3 (Unit-Specific LUT Compensation): Circuit delay drifts caused by manufacturing process variations are compensated by applying a unit-specific calibration curve, derived via 3-sigma filtering and second-order polynomial fitting (R2 = 0.991), stored in non-volatile memory (NVM). Experimental validation across a temperature range of −20 °C to 60 °C demonstrates that the proposed triple compensation reduces the peak-to-peak distance error from 1.11 m to 0.16 m (an 85.6% reduction) and decreases the standard deviation from 0.30 m to 0.035 m (an 88.3% reduction), achieving an 8.57-fold improvement in precision. This approach offers a highly practical and scalable solution for high-precision LiDAR operation without requiring costly physical cooling hardware.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Improved Linearity in Short-Pulse Indirect Time-of-Flight Image Sensors Using Dual-Phase Short-Pulse ModulationSensors · 2026
- A High-Resolution FPGA-Based Time-to-Amplitude Converter (TAC) with Integrated Pulse-Width-Based Walk Error Compensation: Design and Experimental LiDAR ValidationPhotonics · 2026
- Characterization of a 3-D stacked CMOS SPAD depth sensor in 45/22-nm technologyOptics Express · 2026
- A Practical Calibration Method for Correcting Count-Rate Nonlinearity in Free-Running Silicon SPADsPhotonics · 2026
- Fast SPAD-array timing-error correction with time-referencing for non-line-of-sight imaging.Optics express · 2026
- Count-nonlinearity correction of single-photon avalanche diodes using laser superposition and reference-photon-rate validationMeasurement Science and Technology · 2026