Multimethod Evaluation of the Novel Reciproc Minima System: Geometric Design, Mechanical Performance, and Irrigation Dynamics.
Emmanuel J N L Silva, Jorge N R Martins, Victor T L Vieira, Mário Rito Pereira, Ricardo Pinto, Murilo P Alcalde, Marco A H Duarte, Duarte Marques,
Department of Endodontics, Grande Rio University (UNIGRANRIO), Rio de Janeiro 21210-623, RJ, Brazil. · Faculdade de Medicina Dentária, Universidade de Lisboa, 1600-277 Lisboa, Portugal.
Key points
From the paper's conclusion- These findings suggest that low-taper reciprocating instruments may represent a conservative alternative in anatomically challenging canals, while clinicians should consider the associated differences in mechanical behavior and irrigation dynamics when selecting the most appropriate instrument.
Abstract
Objectives: To compare the geometric design, metallurgical properties, mechanical performance, and irrigation dynamics of Reciproc Minima (M20 and M25) and Reciproc Blue R25 instruments. Methods: One hundred and eighty instruments (n = 60/group) were evaluated. Geometry was analyzed using stereomicroscopy, scanning electron microscopy, and 3D surface scanning. Metallurgical characteristics were assessed by energy-dispersive X-ray spectroscopy and differential scanning calorimetry. Mechanical performance tests (n = 10/group) included cyclic fatigue, torsional resistance, bending resistance, buckling resistance, and cutting efficiency. Irrigation dynamics were examined through computational fluid dynamics simulations based on a micro-CT-derived mandibular molar model prepared according to each system and combined with open-ended, side-vented, or double side-vented needles. Data were analyzed using one-way ANOVA or Kruskal-Wallis tests (α = 0.05). Results: The results showed that blade dimensions increased progressively from Minima M20 to Reciproc Blue R25. All instruments had S-shaped cross-sections and non-active tips. Energy-dispersive spectroscopy confirmed near-equiatomic NiTi composition, and similar phase transformation temperatures were observed across groups. Minima M20 showed the highest cyclic fatigue resistance (p < 0.0001), whereas Minima R25 exhibited greater angular deflection (p < 0.0001). Reciproc Blue R25 had the highest buckling resistance and lowest flexibility (p < 0.0001). M25 showed the lowest axial force, indicating the numerically highest cutting efficiency, but it did not differ significantly from Reciproc Blue R25 (p > 0.05). No needle delivered irrigant to working length. The open-ended needle achieved greater apical penetration, particularly with Reciproc Blue R25. Minima M20 generated the highest wall shear stress, and Reciproc Blue R25 the lowest apical pressure. Conclusions: Reciproc Minima and Reciproc Blue R25 showed similar metallurgical characteristics; however, differences in geometric design resulted in distinct mechanical behaviors and irrigation fluid dynamics. These findings suggest that low-taper reciprocating instruments may represent a conservative alternative in anatomically challenging canals, while clinicians should consider the associated differences in mechanical behavior and irrigation dynamics when selecting the most appropriate instrument.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Beyond the Surface: Engineered Nanocoating Reshapes NiTi Instrument Behaviour-A Laboratory Study.International endodontic journal · 2026
- Comparative In Vitro Assessment of Original Reciproc® Blue Instruments vs. Two Replicas: Mechanical Characteristics, Safety, and Efficacy AnalysisOral · 2026
- Cyclic Fatigue Resistance and Fractured Fragment Length of Three NiTi Rotary Systems: An In Vitro ComparisonOral · 2026
- Comparative cyclic fatigue resistance and physical characterization of three commercial NiTi rotary systems under extreme curvatures.Odontology · 2026
- Study on the Effect and Mechanism of Synchronous Irrigation on the Cyclic Fatigue Resistance of Dental Rotary NiTi Instruments.International dental journal · 2026
- Micro-CT Evaluation of Shaping Ability, Canal Transportation, and Centering Ability of Continuous Rotary and Reciprocating Systems in Maxillary Premolars.Medical science monitor : international medical journal of experimental and clinical research · 2026