Odontology

Comparative cyclic fatigue resistance and physical characterization of three commercial NiTi rotary systems under extreme curvatures.

Sarahi Varilla-Echavarria, Guadalupe Nolasco-Villalobos, Marina Vega-González, Taher Al Omari, Luciano Tinajero-Bueno, Uriel Soto-Barreras, Rubén Abraham Domínguez-Pérez

Department of Endodontics, Faculty of Medicine, Autonomous University of Queretaro, Querétaro, Mexico. · Laboratory of Multidisciplinary Dentistry Research, Center for Advanced Biomedical Research, Faculty of Medicine, Autonomous University of Queretaro, Querétaro, Mexico.

Key points

From the paper's conclusion
  • These findings concern the tested commercial products and do not establish the contribution of individual geometric, metallurgical, or surface characteristics or predict clinical performance.

Abstract

This study investigated the cyclic fatigue resistance in simulated severely curved canals and the physical properties of three rotary instruments: AF Blue S One files (AFBlue-f); RCS Rainbow One files (Rainbow-f); and HyFlex EDM files (HyFlex-f). Sixty files with an ISO size 25 tip were evaluated, including instruments with either a 0.04 or variable taper, in two simulated highly curved canals: one with a 120° angle and a 2 mm radius (n = 30), and the other with a 135° angle and a 5 mm radius (n = 30). The number of cycles to fracture and apical fragment lengths were recorded. Fracture surfaces were examined using scanning electron microscopy (SEM). Elemental composition and phase transformation temperatures were explored using energy-dispersive spectroscopy (EDS), energy-dispersive X-ray fluorescence (EDXRF), and differential scanning calorimetry (DSC). Rainbow-f demonstrated a significantly higher number of cycles to fracture and longer apical fragments than AFBlue-f and HyFlex-f in both geometries (all Dunnett T3-adjusted P < 0.05). EDS and EDXRF identified chromium in Rainbow-f, while representative DSC curves showed different phase transformation profiles among the systems. These characterization findings were descriptive. Under static testing at 22 ± 1 °C in the two specified artificial canal geometries, Rainbow-f demonstrated higher cyclic fatigue resistance than the other systems. These findings concern the tested commercial products and do not establish the contribution of individual geometric, metallurgical, or surface characteristics or predict clinical performance.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers