Journal of nuclear medicine : official publication, Society of Nuclear Medicine

Fully Automated Segmentation of [18F]FDG and [68Ga]/[18F]PSMA PET/CT Images via Data-Centric Deep Learning.

Manuel Pires, Sebastian Gutschmayer, Enrica Bergalla, Stephane Chauvie, Dominik Amereller, Elisabetta Abenavoli, Aleksa Lazarevic, Natalia Wegrzyn,

QIMP Team, Medical University of Vienna, Vienna, Austria; manuel.pires@meduniwien.ac.at. · QIMP Team, Medical University of Vienna, Vienna, Austria.

Computational · n=3,031

Key points

From the paper's conclusion
  • We developed and validated LION, an open-source PET-only tumor segmentation pipeline for [18F]FDG and PSMA-targeted PET/CT, and investigated how training data characteristics influence segmentation performance.
  • Organ context improved median Dice from 0.62 to 0.71 for [18F]FDG and from 0.75 to 0.83 for PSMA, on the complete holdout cohorts, and spatial diversity measured by TOMs was strongly associated with Dice.
  • LION enables PET-only automated segmentation for [18F]FDG and PSMA-targeted PET, with training data composition, particularly spatial diversity quantified by TOMs, strongly associated with segmentation performance.

Abstract

The purpose of this study was to develop and validate lesion identification in oncologic nuclear imaging (LION), an open-source PET-only tumor segmentation pipeline for [18F]FDG and prostate-specific membrane antigen (PSMA)-targeted PET/CT, and to investigate how training data characteristics influence segmentation performance. Methods: In this retrospective multicenter study, 5209 [18F]FDG PET/CT scans spanning 19 disease types and 2046 PSMA-targeted PET/CT scans were used to train PET-only segmentation models. Tumor segmentation incorporated organs with physiologic uptake as auxiliary classes to enable PET-only inference. Tumor occurrence maps (TOMs) quantified tumor spatial diversity across the training data. For [18F]FDG, disease-specific and mixed-disease models trained on progressively larger subsets were compared to test whether increasing spatial diversity improves generalization. Scanner-related domain shift was analyzed using DINOv2 embeddings. Models were evaluated on multicenter holdout cohorts (616 [18F]FDG scans across 4 diseases; 443 PSMA-targeted prostate cancer scans) and compared with 3 open-source tools. Results: Organ context improved median Dice from 0.62 to 0.71 for [18F]FDG and from 0.75 to 0.83 for PSMA, on the complete holdout cohorts. Spatial diversity measured by TOMs was strongly associated with Dice (Spearman ρ = 0.80, P = 0.003). A mixed-disease model trained on 500 patients matched the performance of a lymphoma specialist model trained on 3031 cases. DINOv2 embeddings revealed scanner-induced domain shift between same-disease cohorts. LION achieved median Dice scores of 0.71 for [18F]FDG and 0.85 for PSMA and outperformed other open-source approaches on the model-comparison test set, which excluded the AutoPET test cases. Conclusion: LION enables PET-only automated segmentation for [18F]FDG and PSMA-targeted PET. Training data composition, particularly spatial diversity quantified by TOMs, was strongly associated with segmentation performance.

Read the paper

Discussion · 1

Science Skim's AI key points, plus readers' public thoughts

Science SkimAI key points
Pinned
  • We developed and validated LION, an open-source PET-only tumor segmentation pipeline for [18F]FDG and PSMA-targeted PET/CT, and investigated how training data characteristics influence segmentation performance.
  • Organ context improved median Dice from 0.62 to 0.71 for [18F]FDG and from 0.75 to 0.83 for PSMA, on the complete holdout cohorts, and spatial diversity measured by TOMs was strongly associated with Dice.
  • LION enables PET-only automated segmentation for [18F]FDG and PSMA-targeted PET, with training data composition, particularly spatial diversity quantified by TOMs, strongly associated with segmentation performance.

Readers' thoughts

No reader thoughts yet.

Related papers